As an Amazon Associate, we earn from qualifying purchases.

Motor Starter Kit, TeSys, LC1D09G7 contactor, GV2P02 motor starter protector, 120 VAC 50/60 Hz coil, 0.16 to 0.25A trip | Mayer Electric

Gallery

Attributes

Brand name, Manufacturer name, ManufacturerSQUARE D
Attribute00RINA || DNV || GOST || LROS (Lloyds register of shipping) || UL || GL || BV || CCC || CSA
Attribute01120 V AC 50/60 Hz
Attribute021.56 W AC-1 || 0.2 W AC-3
Attribute032.5 mOhm - Ith 25 A 50 Hz power circuit
Attribute041 NO + 1 NC
Attribute0525 A 60 ?C power circuit || 10 A 60 ?C signalling circuit
Attribute06yes IEC 60947-4-1
Attribute07rail || plate
Attribute08AC 50/60 Hz
Attribute09CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Attribute10B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Attribute11resistive load || motor control
Attribute12250 A 440 V power circuit IEC 60947
Attribute13motor starter
Attribute14250 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
Attribute156 kV IEC 60947
Attribute16power circuit screw clamp terminals 1 1-4 mm?flexible without cable end || power circuit screw clamp terminals 2 1-4 mm?flexible without cable end || power circuit screw clamp terminals 1 1-4 mm?flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm?flexible with cable end || power circuit screw clamp terminals 1 1-4 mm?solid without cable end || power circuit screw clamp terminals 2 1-4 mm?solid without cable end || control circuit screw clamp terminals 1 1-4 mm?flexible without cable end || control circuit screw clamp terminals 2 1-4 mm?flexible without cable end || control circuit screw clamp terminals 1 1-4 mm?flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm?flexible with cable end || control circuit screw clamp terminals 1 1-4 mm?solid without cable end || control circuit screw clamp terminals 2 1-4 mm?solid without cable end
Attribute17TeSys
Attribute183 NO
Attribute19AC-3 || AC-1 || AC-4
Attribute203600 cyc/h 60 ?C
Attribute21yes IEC 60947-1
Attribute22power circuit 1.7 N.m screw clamp terminals flat ? 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat ? 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
Attribute230.16-0.25 A
Attribute2415 Mcycles
Attribute253P
Attribute2612...22 ms closing || 4...19 ms opening
Attribute27III
Attribute282.2 kW 220...230 V AC 50/60 Hz AC-3) || 4 kW 380...400 V AC 50/60 Hz AC-3) || 4 kW 415...440 V AC 50/60 Hz AC-3) || 5.5 kW 500 V AC 50/60 Hz AC-3) || 5.5 kW 660...690 V AC 50/60 Hz AC-3) || 2.2 kW 400 V AC 50/60 Hz AC-4)
Attribute291 hp 230/240 V at AC 50/60 Hz for 1 phase || 2 hp 200/208 V at AC 50/60 Hz for 3 phase || 2 hp 230/240 V at AC 50/60 Hz for 3 phase || 5 hp 460/480 V at AC 50/60 Hz for 3 phase || 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase || 0.33 hp 115 V at AC 50/60 Hz for 1 phase
Attribute30power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
Attribute31thermal-magnetic
Attribute32105 A 40 ?C - 10 s power circuit || 210 A 40 ?C - 1 s power circuit || 30 A 40 ?C - 10 min power circuit || 61 A 40 ?C - 1 min power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
Attribute33with
Attribute341.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Attribute355 mA signalling circuit
Attribute360.25 A
Attribute37, Attribute63690 V AC 50/60 Hz IEC 60947-2
Attribute38screw clamp terminals 2 1-6 mm? solid || screw clamp terminals 2 1.5-6 mm? flexible without cable end || screw clamp terminals 2 1-4 mm? flexible with cable end
Attribute39drop-out 0.3...0.6 Uc AC 50/60 Hz 60 ?C) || operational 0.8...1.1 Uc AC 50 Hz 60 ?C) || operational 0.85...1.1 Uc AC 60 Hz 60 ?C)
Attribute40continuous IEC 60947-4-1
Attribute41M2
Attribute422.4-2.4 A
Attribute430.25 A IEC 60947-4-1
Attribute440.06-0.06 kW 400/415 V AC 50/60 Hz
Attribute45> 10 MOhm signalling circuit
Attribute4625 cyc/h
Attribute47any position
Attribute480-0.5 kW 100-120 V 3 phase || 0.55-1 kW 100-120 V 3 phase || 0-0.5 kW 200-240 V 3 phase || 0.55-1 kW 200-240 V 3 phase || 1.1-2 kW 200-240 V 3 phase || 0-0.5 kW 380-440 V 3 phase || 0.55-1 kW 380-440 V 3 phase || 1.1-2 kW 380-440 V 3 phase || 2.2-3 kW 380-440 V 3 phase || 4-6 kW 380-440 V 3 phase || 0-0.5 kW 480-500 V 3 phase || 0.55-1 kW 480-500 V 3 phase || 1.1-2 kW 480-500 V 3 phase || 2.2-3 kW 480-500 V 3 phase || 4-6 kW 480-500 V 3 phase || 0-0.5 kW 525-690 V 3 phase || 0.55-1 kW 525-690 V 3 phase || 1.1-2 kW 525-690 V 3 phase || 2.2-3 kW 525-690 V 3 phase || 4-6 kW 525-690 V 3 phase
Attribute49AC-3 IEC 60947-4-1 || category A IEC 60947-2
Attribute5070-70 VA 60 Hz 0.75 20 ?C) || 70-70 VA 50 Hz 0.75 20 ?C)
Attribute5135 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws)
Attribute526 kV IEC 60947-2
Attribute53100 % 690 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2
Attribute54rotary knob
Attribute55without built-in suppressor module
Attribute562.5 W
Attribute57100000 cycles AC-3 440 V
Attribute58direct on-line contactor
Attribute5917 V signalling circuit
Attribute60100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Attribute61100000 cycles
Attribute6225...400 Hz
Attribute641.7 N.m screw clamp terminals
Attribute65without
Attribute66mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Attribute677.5-7.5 VA 60 Hz 0.3 20 ?C) || 7-7 VA 50 Hz 0.3 20 ?C)
Attribute6850/60 Hz IEC 60947-4-1
Attribute692-3 W 50/60 Hz
Attribute70, Attribute71Yes
Attribute72ENVPEP121004EN
Attribute73Green Premium product
Attribute74Reference contains Substances of Very High Concern above the threshold
Attribute75Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Attribute76Product out of China RoHS scope. Substance declaration for your information.
Attribute77ENVEOLI121004EN
Attribute78Compliant
Attribute79IK04
Attribute80vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Attribute81-20-60 ?C
Attribute82-5-60 ?C
Attribute8377 mm
Attribute84VDE 0660 || NF C 63-650 || CSA C22.2 || VDE 0113 || IEC 60947-4-1 || UL 508 || EN 60204 || NF C 63-120 || IEC 60947-1 || IEC 60947-2 || NF C 79-130
Attribute85IACS E10
Attribute863
Attribute87UL || DNV || EAC || GL || ATEX || CCC || BV || UL 508 type E || RINA || TSE || EZU || CSA || LROS (Lloyds register of shipping)
Attribute880.32 kg
Attribute8997 mm
Attribute90V1 conforming to UL 94
Attribute91-60-80 ?C
Attribute92-40-80 ?C
Attribute9345 mm
Attribute9489 mm
Attribute95TH
Attribute96IP20 IEC 60529
Attribute97IP20 front face IEC 60529
Attribute986561.68 ft (2000 m)
AttributeKey00, AttributeKey87Product Certifications
AttributeKey01[Uc] Control Circuit Voltage
AttributeKey02, AttributeKey56Power Dissipation Per Pole
AttributeKey03Average Impedance
AttributeKey04Auxiliary Contact Composition
AttributeKey05, AttributeKey43[Ith] Conventional Free Air Thermal Current
AttributeKey06Phase Failure Sensitivity
AttributeKey07Mounting Support
AttributeKey08Control Circuit Type
AttributeKey09, AttributeKey84Standards
AttributeKey10Safety Reliability Level
AttributeKey11Contactor Application
AttributeKey12Rated Breaking Capacity
AttributeKey13Product Or Component Type
AttributeKey14Irms Rated Making Capacity
AttributeKey15, AttributeKey52[Uimp] Rated Impulse Withstand Voltage
AttributeKey16, AttributeKey38Connections - Terminals
AttributeKey17Range
AttributeKey18Pole Contact Composition
AttributeKey19, AttributeKey49Utilisation Category
AttributeKey20, AttributeKey46Maximum Operating Rate
AttributeKey21Suitability For Isolation
AttributeKey22, AttributeKey64Tightening Torque
AttributeKey23Trip Unit Rating
AttributeKey24, AttributeKey61Mechanical Durability
AttributeKey25Poles Description
AttributeKey26Operating Time
AttributeKey27Overvoltage Category
AttributeKey28, AttributeKey44Motor Power Kw
AttributeKey29Maximum Horse Power Rating
AttributeKey30, AttributeKey63[Ui] Rated Insulation Voltage
AttributeKey31Trip Unit Technology
AttributeKey32[Icw] Rated Short-Time Withstand Current
AttributeKey33Protective Cover
AttributeKey34Non-Overlap Time
AttributeKey35Minimum Switching Current
AttributeKey36Line Rated Current
AttributeKey37[Ue] Rated Operational Voltage
AttributeKey39Control Circuit Voltage Limits
AttributeKey40Rated Duty
AttributeKey41Contact Compatibility
AttributeKey42Magnetic Tripping Current
AttributeKey45Insulation Resistance
AttributeKey47Operating Position
AttributeKey48Power Range
AttributeKey50Inrush Power In Va
AttributeKey51Fixing Mode
AttributeKey53[Ics] Rated Service Short-Circuit Breaking Capacity
AttributeKey54Control Type
AttributeKey55Coil Technology
AttributeKey57Electrical Durability
AttributeKey58Motor Starter Type
AttributeKey59Minimum Switching Voltage
AttributeKey60Breaking Capacity
AttributeKey62Signalling Circuit Frequency
AttributeKey65Direct Connector
AttributeKey66Auxiliary Contacts Type
AttributeKey67Hold-In Power Consumption In Va
AttributeKey68Network Frequency
AttributeKey69Heat Dissipation
AttributeKey70Rohs Exemption Information
AttributeKey71Mercury Free
AttributeKey72Environmental Disclosure
AttributeKey73Sustainable Offer Status
AttributeKey74Reach Regulation
AttributeKey75California Proposition 65 : WARNING: This product can expose you to chemicals including
AttributeKey76China Rohs Regulation
AttributeKey77Circularity Profile
AttributeKey78Eu Rohs Directive
AttributeKey79Ik Degree Of Protection
AttributeKey80Mechanical Robustness
AttributeKey81, AttributeKey82Ambient Air Temperature For Operation
AttributeKey83, AttributeKey94, height_AttribHeight
AttributeKey85Climatic Withstand
AttributeKey86Pollution Degree
AttributeKey88, Weight_AttribNet Weight
AttributeKey89, length_AttribDepth
AttributeKey90Flame Retardance
AttributeKey91, AttributeKey92Ambient Air Temperature For Storage
AttributeKey93, width_AttribWidth
AttributeKey95Protective Treatment
AttributeKey96, AttributeKey97Ip Degree Of Protection
AttributeKey98Operating Altitude
DimensionUnitmm
Extra Product NameMotor Starter Kit, TeSys, LC1D09G7 contactor, GV2P02 motor starter protector, 120 VAC 50/60 Hz coil, 0.16 to 0.25A trip | Mayer Electric
UPC, MPN, SKUSQDGV2P02KD09G7
Weight0.32
WeightUnitkg
depth, length97.0
height77.0
jsonUrlData/Product/SQUARE-D-Motor-Starter-Kit-TeSys-LC1D09G7-contactor-GV2P02-motor-starter-protector-120-VAC-50-60-Hz-coil-0-16-to-0-25A-trip-SQDGV2P02KD09G7
jsonUrlData2a24a0393-90e0-422c-8b58-ade40063f88f
moq, multiple, tierMinQty11
qtyInStock0
tierPrice10.00
width45.0

Distributor offers

SellerSKUMOQIn stockMultiplePrices
mayerelectric.comSQDGV2P02KD09G7111 @ $0.00