Definite Purpose Starter, Mounting Style Bolt On, Surface, Number of Auxillary Contacts 1, Includes Auxiliary Contacts Yes, Horsepower @ Three Phase - 208V AC 10 hp, Series A27, Coil Voltage 110-120V AC, Terminal Connection Type Box Lugs, Horsepower @ Three Phase - 600V AC 15 hp, Maximum Voltage Rating 600V AC, Horsepower @ Three Phase - 480V AC 15 hp, Horsepower @ Three Phase - 240V AC 10 hp, Horsepower @ Single Phase - 240V AC Not Rated, Horsepower @ Single Phase - 120V AC Not Rated
Definite Purpose Starter, Mounting Style Bolt On, Surface, Number of Auxillary Contacts 1, Includes Auxiliary Contacts Yes, Horsepower @ Three Phase - 208V AC Not Rated, Series B27, Coil Voltage 24V AC, Terminal Connection Type Screw Terminals, Horsepower @ Three Phase - 600V AC Not Rated, Maximum Voltage Rating 600V AC, Horsepower @ Three Phase - 480V AC Not Rated, Horsepower @ Three Phase - 240V AC Not Rated, Horsepower @ Single Phase - 240V AC 2 hp, Horsepower @ Single Phase - 120V AC 3/4 hp
IEC Magnetic Contactor, Full Load Amps-Inductive 12 A, Full Load Amps-Resistive 22 A, Number of Poles 3, Coil Volts 480 V AC, Reversing Yes, HP @ 1 Phase - 120V 1/2 hp, HP @ 1 Phase - 240V 2 hp, HP @ 3 Phase - 208V 3 hp, HP @ 3 Phase - 240V 3 hp, HP @ 3 Phase - 480V 10 hp, HP @ 3 Phase - 575V 10 hp, Aux. Contact Configuration 2NO/1NC, Enclosure NEMA Rating No Enclosure, Hz 50/60, Height 3.54 in, Width 3.54 in, Depth 4.92 in, Standards UL/CE/CSA/CCC/ATEX/IEC EN 60947
Mercury Displacement Contactor, Coil Voltage 240V AC, Contact Form 2NO, Contact Material Liquid Mercury, Number of Poles 2, Mounting Style Surface, Horsepower @ Three Phase - 600V AC 15 hp, Horsepower @ Three Phase - 480V AC 15 hp, Horsepower @ Single Phase - 240V AC 10 hp, Horsepower @ Single Phase - 120V AC 5 hp, Horsepower @ Three Phase - 240V AC 10 hp, Terminal Connection Type Screw Terminals, AC Full Load Current - Inductive @ Single Phase 28 A
Mercury Displacement Contactor, Contact Form DPST, Coil Volts 240V AC, Contact Amp Rating (Resistive) 35 A, Depth 2.54 in, Height 4.95 in, Width 3.51 in, Number of Poles 2, Contact Material Liquid Mercury, Mounting Position Vertical within 10 Degrees , HP @ 1 Phase - 120V 5 hp, HP @ 1 Phase - 240V 5 hp, HP @ 3 Phase - 240V 7 1/2 hp, HP @ 3 Phase - 480V 10 hp, HP @ 3 Phase - 600V 10 hp, Coil VA Rating 7 to 28, Hz 50/60
NEMA Magnetic Motor Starter, Overload Relay Amp Setting 30 to 150A, Coil Volts 208V AC, Enclosure NEMA Rating 3R, Auxiliary Contact Form 1NC/1NO, HP @ 3 Phase - 240V 50 hp, HP @ 3 Phase - 480V 100 hp, Starter Type NEMA Style, Action Nonreversing, Hz 60, Number of Poles 3, Amps AC 135, NEMA Size 4, Width 14.25 in, Features Solid State Overload Relay, Includes Solid State Overload Relay, HP @ 3 Phase - 575V 100 hp, HP @ 3 Phase - 208V 40 hp, Height 29.1 in, Depth 8.47 in, Standards CSA, UL