Product_description: ['<b>Features</b><br>Universal AC input / Full range<br>3 Pole AC inlet IEC320-C14, Class I Power Unit <br>Medical safety approved ( 2 * MOPP) according to ANS/AAMI ES60601-1 and IEC/EN60601-1<br>Extremely low leakage current<br>No load power consumption<0.1W<br>Engergy efficiency Level VI ( except 5~9V for level V)<br>-30~+70°C wide range working temperature<br>Protections: Short circuit / Overload / Over voltage<br>LED indicator for power on<br>Lifetime>105 K hours<br>3 years warranty <br><b>Description</b><br>GSM60A is a highly reliable, 60W single-output green medical adaptor series. This product is a class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 80VAC to 264VAC.<br>The entire series supplies different models with output voltages between 5VDC and 48VDC that can satisfy the demands for various types of medical electrical devices.<br> The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<90uA), fitting the medical devices in direct electrical contact with the patients.<br><br>With the efficiency up to 91% and the extremely low no-load power consumption below 0.1W, GSM60A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU Erp and meet Code of Conduct(CoC) Version 5 ; <br>the adapter to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case,GSM60A is certified with the international medical safety regulations.', '<b>Features</b><br>Universal AC input / Full range<br>Medical safety approved(2xMOPP)<br>Suitable for BF application with appropriate system consideration (B-Type only)<br>low leakage current <50uA(100uA for A Type)<br>No load power consumption <0.1W<br>Energy efficiency Level VI (5~9V for Level V)<br>Comply with EISA 2007/DoE, NRCan, AU/NZ MEPS, EU ErP and meet CoC Version 5<br>High efficiency up to 91.5%<br>A-Type: Class I(with earth Pin) B-Type: Class II(without earth Pin)<br>Protections: Short circuit / Overload / Over voltage / Over temp.(GSM60 A/B)<br>Fully enclosed plastic case<br>LED indicator for power on<br>Optional lock type DC plug<br>3 years warranty', '<b>Features</b><br>Universal AC input / Full range<br>Medical safety approved(2xMOPP)<br>Suitable for BF application with appropriate system consideration (except for GSM40A/60A )<br>Low leakage current < 50μA(<100μA for GSM40A/60A/90B)<br>No load power consumption <0.1W(<0.15W for GSM90B)<br>Energy efficiency Level VI (except GSM40/60 5~9V for Level V)<br>Comply with EISA 2007/DoE, NRCan, AU/NZ MEPS, EU ErP and meet CoC Version 5<br>Built-in active PFC function(GSM90B) <br>High efficiency up to 91.5%<br>A-Type: Class I(with earth Pin)<br>B-Type: Class II(without earth Pin)<br>Protections: Short circuit / Overload / Over voltage /Over temp.(except for GSM40)<br>Fully enclosed plastic case<br>LED indicator for power on<br>Optional lock type DC plug<br>3 years warranty', '<p><b>Features:</b></p> <p>3 pole AC inlet IEC320-C14 , Class I power unit</p> <p>Medical safety approved (2 x MOPP) accroding to ANSI/AAMI ES60601-1 and IEC/EN60601-1</p> <p>Extremely low leakage current</p> <p>No load power consumption< 0.1W</p> <p>Energy efficiency Level VI and meet CoC Version 5(Except 5~9V for Level V)</p> <p>-30~ +70ºC wide range working temperature</p> <p>Protections: Short circuit / Overload / Over voltage / Over temperature </p> <p>LED indicator for power on</p> <p>Lifetime > 105K hours</p> <p>3 years warranty</p> <p></p> <p><b>General Specification:</b></p> <p>AC input voltage range: 80~264VAC 113~370VDC</p> <p>AC inrush current (Typ.):Cold start 30A/115VAC 60A/ 230VAC</p> <p>AC adjustment range: 5V: 0.1~6A, 7.5V: 0.1~6A, 9V: 0.1~6A, 12V: 0.1~5A, 15V: 0.1~4A, 18V: 0.1~3.33A, 24V: 0.1~2.5A ,48V: 0.1~1.25A</p> <p>Over voltage protection: 5V: 5.2~7V, 7.5V: 7.8~10.2V, 9V: 9.4~12.2V, 12V: 12.6~16.2V, 15V: 15.7~20.3V, 18V: 18.9~24.3V, 24V: 25.2~32.4V ,48V: 50.4~64.8V, Protection type : Shut down o/p voltage, re-power on to recover</p> <p>Overload protection: 105 ~ 160% rated output power,Protection type :Hiccup mode, recovers automatically after fault condition is removed</p> <p>Over temperature: Shut down o/p voltage, re-power on to recover</p> <p>Withstand voltage:I/P-O/P: 4KVAC ,I/P-F/G: 2KVAC ,O/P-F/G: SHORT</p> <p>Working temperature: -30~ +70ºC (Refer to "Derating Curve")</p> <p>Safety standards:IEC60601-1,TUV EN60601-1,ANSI/AAMI ES60601-1(3.1 version),CAN/CSA-C22.2 No.60601-1:14-Edition 3, EAC TP TC 004 approved</p> <p>EMC standards: EN55011 (CISPR11), FCC PART 15/ CISPR22,CAN ICES-3(B)/NMB-3(B) Class B, EN61000-3-2,3,EN61000-4-2-3,4,5,6,8,11</p> <p>Isolation resistance:I/P-O/P , I/P-F/G:100M Ohms/500VDC/25ºC/70% RH</p> <p>Dimension (LxWxH) (mm):125x 50x 31.5</p>', 'Plug-In Adapter Single-OUT 12V 5A 60W Medical', 'This item will ship GSM60A12-P1J*1pcs,enjoy shopping and best wishes!']

Products with this attribute (1 total)