<p><strong>Aalborg, GFM47A-VDL6-A0-3HD-40-SS, GFM Thermal Mass Flow Meter Aluminum, Viton-A Seals, 3/8" Compression, LCD Readout Display, Universal +12 to +26 VDC, 0-5 VDC, Hydrogen H2 0-60, L/Min, 14.7 psia Metering Pressure, 21.1 Deg C / 70 Deg F Temperature </strong> </p> <p><strong>GFM mass flow meter </strong> </p> <p>A low cost solution to thermal mass flow metering for gases is presented by Aalborg in introducing the model GFM mass flow meter line. The GFM design combines the convenience and accuracy of conventional mass flow devices with low costs previously unattainable. </p> <p><strong>Principles of Operation </strong> </p> <p>Metered gases are divided into two laminar flow paths, one through the primary flow conduit, and the other through a capillary sensor tube. Both flow conduits are designed to ensure laminar flows and therefore the ratio of their flow rates is constant. Two precision temperature sensing windings on the sensor tube are heated, and when flow takes place, gas carries heat from the upstream to the downstream windings. The resultant temperature differential is proportional to the change in resistance of the sensor windings. A Wheatstone bridge design is used to monitor the temperature dependent resistance gradient on the sensor windings which is linearly proportional to the instantaneous rate of flow. Flow rates are unaffected by temperature and pressure variations within stated limitations. </p> <p><strong>General Description </strong> </p> <p>Compact, self contained GFM mass flow meters are designed to read flow rates of gases. The rugged design coupled with instrumentation grade accuracy provides versatile and economical means of flow control. Transducer power supply ports are fuse and polarity protected. </p>

Attributes

Key ^Value
Attitude SensitivityNo greater than +15 degree rotation from horizontal to vertical; standard calibration is in horizontal position
CalibrationsPerformed at standard conditions [14.7 psia (101.4 kPa) and 70 ?F (21.1 ?C)]
CE CompliantEN 55011 class 1, class B; EN50082-1
Digital InterfaceNone
DisplayLCD Readout
Fittings3/8" Compression
MaterialAluminum
Output Signal0-5 VDC
PowerUniversal +12 to +26 VDC
Pressure Coefficient0.01% of full scale / psi (0.07 bar)
Repeatability?0.25% of full scale
Response TimeGenerally 2 seconds to within ?2% of actual flow rate over 25 to 100% of full scale
SealsViton-A
Temperature Coefficient0.15% of full scale / ?C