Accuracy | ?0.5% FS (includes linearity, hysteresis & repeatability) |
Agency Approvals | CE |
Compensated Temperature Limits | 0 to 175 F |
Current Consumption | 28 mA max. |
Display | 4-1/2 digit LCD field attachable display |
Electrical Connections | Removable terminal block |
Enclosure Rating | Designed to meet NEMA 4X (IP66) |
Loop Resistance | Voltage output: Minimum load resistance = 5 k? |
Mounting Orientation | Not position sensitive |
Output Signal | 3-wire: Field selectable 0 to 5, 1 to 5, 0 to 10, or 2 to 10 VDC |
Power Requirements | 3-wire: 13 to 35 VDC or isolated 16 to 33 VAC (reverse polarity protected) |
Pressure Limits | 0 to 10 psid |
Process Connections | 1/4" Male NPT |
Response Time | 400 msec |
Service | Compatible gases and liquids. |
Stability | ?1% FS/year |
Temperature Limits | 0 to 200 F |
Thermal Effect | Avg 0.04%/ F (includes zero and span) |
Weight | 10.1 oz |
Wetted Materials | 316, 316L SS |
Zero and Span Adjustments | Push buttons inside conduit enclosure |