prev
Flowline UG12-0001-00
Flowlinezoom
brand:
manufacturer:
Description:
<p><strong>Flowline, UG12-0001-00, EchoPod Reflective Ultrasonic Liquid Level Transmitter, 12 m. (39.3') Sensor Range, 3" NPT Process Mount without FOB Adapter </strong> </p> <p><strong>Features: </strong> </p> <ul><li>Offered in 12 m. (39.3') measurement ranges </li> <li>Reflective Technology measures reliably with condensation </li> <li>Corrosion resistant PVDF transducer with IP68 PP enclosure </li> <li>Fail-safe diagnostics with selectable signal fail-safe outputs </li> <li>LCD display indicates level in inches, meters or percent of span </li> <li>Narrow 3" (7.6 cm.) beam width for applications with limited space </li> <li>Windowed enclosure cap provides liquid tight level indication </li> <li>Automatic temperature compensation from -40? to 80? C </li> </ul> <p><strong>Applications: </strong> </p> <p>The general purpose reflective ultrasonic level transmitter provides continuous level measurement up to 39.3' (12 m.) with a 4-20 mA analog signal output. The non-contact liquid level sensor features proprietary Reflective Technology that delivers reliable level measurement in condensing environments. Select this sensor for bulk tanks with non-foaming or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include bulk storage, neutralization tank, clarifier and waste sumps. </p> <p><strong>Reflective: </strong> </p> <p>Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50% and substantially reducing their measurement reliability. At the core of Reflective Technology is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45? reflector, delivering reliable level measurement. Thanks gravity. </p>

Attributes

Key Value
Accuracy? 0.2% of range
Ambient temp.F: -31? to 140? / C: -35? to 60?
ApprovalUL 61010-1
Beam width6" (15.2 cm.)
ClassificationGeneral purpose
ComplianceCE, RoHS
Conduit entrance1/2" NPT
ConfigurationPush button or WebCal PC Windows USB 2.0
Dead band18" (45.7 cm.)
Display typeLCD, 6-digit
Display unitsInch, cm or percent
Encl. cap materialClear polycarbonate
Encl. materialPolypropylene
Enclosure ratingType 6P (IP68)
Enclosure ventWater tight membrane
Loop resistance500 ohms at 24 VDC
Max. consumption0.5W
MemoryNon-volatile
Mount gasketN/A
Pressure30 psi (2 bar)
Process mount3" NPT
Process temp.F: -40? to 176? / C: -40? to 80?
Range18" to 39.3' (45.7 cm to 12 m.)
Resolution0.196" (5 mm.)
Signal fail-safe4mA, 20mA, 21mA, 22mA, hold last
Signal invert4-20mA or 20-4mA
Signal output4-20mA, two-wire
Supply voltage14-28 VDC
Temp. comp.Automatic
Transducer mat.Polyvinylidene fluoride
Transducer typeReflective