Attributes

Key Value
[Ie] Rated Operational .3 A 240 V, AC-15, A300 .
[Ithe] Conventional Enc.10 A
[Ui] Rated Insulation V.500 V 3)EN/IEC 60947-1 .
[Uimp] Rated Impulse Wi.6 kV EN/IEC 60947-1
Ambient Air Temperature.-25-70 ?C
Ambient Air Temperature.-40-70 ?C
Body Materialzamak
Cable Entry Number3 plain hole Pg 13.5 or.
California Proposition .Diisononyl phthalate (D.
Compatibility CodeXY2CE
Connections - Terminalsscrew clamp terminal, 1.
Contact Operationslow-break
Contacts Type And Compo.1 NC + 1 NO
Cover Materialstainless steel
Device Short NameXY2CE
Distance Between Cable .5-5 m
Environmental DisclosureENVPEP111159EN
Eu Rohs DirectiveNot applicable, out of .
Housing Colourred RAL 3000
Ip Degree Of ProtectionIP65 IEC 60529
Key Number421
Local Signallingwithout pilot light
MarkingCE
Maximum Resistance Acro.25 MOhm EN/IEC 60255-7 .
Mechanical Durability60000 cycles
Net Weight1.465 kg
Number Of Cables1
Overvoltage Categoryclass I EN/IEC 61140 ||.
Positive Openingwith EN/IEC 60947-5-1
Product CertificationsUL category NISD emerge.
Product Or Component Ty.latching emergency stop.
Protective TreatmentTC
Range Of ProductTelemecanique Emergency.
Reach RegulationReference contains Subs.
Resetby key-release push-but.
Safety Levelcan reach PL = e with t.
Safety Reliability DataB10d = 300000 value giv.
Shock Resistance50 gn 11 ms EN/IEC 6006.
Short-Circuit Protection10 A cartridge fuse gG .
StandardsEN/IEC 60947-5-5 || CSA.
Terminals Description I.(13-14)NO || (21-22)NC
Tightening Torque0.8-1.2 N.m
Trigger Cable Anchor Po.LH side
Trigger Cable Maximum L.70 m
Vibration Resistance10 gn 10-300 Hz)EN/IEC .
Warranty18 months