[Ui] Rated Insulation Voltage | 300 VUL 508 || 300 VCSA C22.2 No 14 || 500 V 3)EN/IEC 60947-1 |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60664 || 6 kV EN/IEC 60947-1 |
Ambient Air Temperature For Operation | -40-70 ?C |
Ambient Air Temperature For Storage | -40-85 ?C |
Body Material, Head Material | zamak |
Body Type | fixed |
Cable Entry | 3 entries tapped for Pg 13.5 cable gland 9-12 mm |
California Proposition 65 : WARNING: This product can expose you to chemicals including | Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Contact Block Per Direction [Control Circuit] | 1 per direction |
Contact Code Designation | A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 appendix A || Q150, DC-13 (Ue = 125 V), Ie = 0.55 A EN/IEC 60947-5-1 appendix A |
Contact Operation | slow-break, staggered |
Contacts Insulation Form | Zb |
Contacts Type And Composition | 2 x (2 NC) |
Depth | 59 mm |
Device Short Name | XCKMR |
Electrical Connection | screw-clamp terminals 1 x 0.5...2 x 2.5 mm? |
Electrical Shock Protection Class | class I IEC 60536 |
Environmental Disclosure | ENVPEP110614EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Fixing Mode | by the body |
Head Type | rotary head |
Height | 118-118 mm |
Ik Degree Of Protection | IK07 EN 50102 |
Ip Degree Of Protection | IP66 conforming to EN/IEC 60529 |
Material | metal |
Maximum Actuation Speed | 1.5 m/s actuation point on the rod between 65 and 95 mm |
Maximum Displacement Angle | -180 ? || 180 ? |
Maximum Resistance Across Terminals | 25 MOhm IEC 60255-7 category 3 |
Mechanical Durability | 2000000 cycles |
Mercury Free, Rohs Exemption Information | Yes |
Minimum Actuation Speed | 6 m/min |
Minimum Torque For Tripping | 0.5 N.m |
Movement Of Operating Head | rotary |
Net Weight | 0.55 kg |
Number Of Poles | 4 |
Number Of Steps | 5 electrical positions |
Positive Opening | with |
Positive Opening Minimum Torque | 0.75 N.m |
Product Certifications | UL || CCC || CSA || CE |
Product Or Component Type | limit switch |
Product Specific Application | for hoisting and mechanical handling applications |
Protective Treatment | TC |
Range Of Product | OsiSense XC |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Series Name | special format |
Shock Resistance | 50 gn EN/IEC 60068-2-27 |
Short-Circuit Protection | 10 A cartridge fuse gG |
Standards | EN/IEC 60947-5-1 || UL 508 || CSA C22.2 No 14 |
Sustainable Offer Status | Green Premium product |
Switch Actuation | by any moving part |
Terminals Description Iso N?1 | (11-12)NC || (21-22)NC |
Type Of Approach | lateral approach, 2 directions |
Type Of Operator | stay put crossed rods lever metal square rod 6 mm, L = 200 mm |
Vibration Resistance | 25 gn 10-500 Hz)EN/IEC 60068-2-6 |
Warranty | 18 months |
Width | 200 mm |