| AC Current (Typ.) | 1.4A / 115VAC------0.6A / 230VAC-------0.55A / 277VAC |
| Dimension | 220 x 68 x 38.8mm (LxWxH) |
| Dimensions | 220 x 68 x 38.8mm |
| Efficiency (Typ.) (230Vac) | 93% |
| EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 4KV), criteria A |
| Hold up Time | 12ms at full load 230VAC/115VAC |
| Industry Aliases | new |
| Input Voltage | 90~305VAC |
| Inrush Current (Typ.) | COLD START 60A (twidth=415?S measured at 50% lpeak) at 230VAC |
| Isolation Resistance | I/P - O/P, I/P-FG, O/P-FG : 100M Ohms / 500VDC / 25?C / 70% RH |
| Leakage Current | <0.75mA / 277VAC |
| Line Regulation, Load Regulation | ?0.5% |
| MTBF | 192.2K hrs min. MIL-HDBK-217F (25?C) |
| Number of Outputs | 1 |
| Output Voltage | 20V |
| Over Current | 95 ~ 106% |
| Over Temperature | 85?C?10?C (RTH2) |
| Over Voltage | 23 ~ 27V |
| Packing | 1.12Kg; 12pcs / 14.4Kg / 0.8CUFT |
| Power Factor (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve) |
| Storage Temp., Humidity | -40 ~ +80?C, 10 ~ 95% RH |
| Temp. Coefficient | ?0.03%/?C (0 ~ 50?C) |
| Vibration | 10 ~ 500Hz, 5G 12min. / 1cycle, period for 72min. each along X, Y, Z axes |
| Voltage Range | 90~305VAC 127~431VDC |
| Voltage Tolerance | ?1.0% |
| Wattage | 120 |
| Withstand Voltage | I/P - O/P : 3.75KVAC-----I/P-FG : 2KVAC---- O/P-FG : 0.5KVAC |
| Working Humidity | 20 ~ 95% RH non-condensing |
| Working Temp. | -40 ~ +70?C (Refer to "Derating Curve") |