AC Current (Typ.) | 0.8A / 115VAC------0.4A / 230VAC--------0.32A / 277VAC |
Dimension | 162.5 x 43 x 32mm (LxWxH) |
Dimensions | 162.5 x 43.5 x 32 mm |
Efficiency (Typ.) | 86% |
EMC Emission | Compliance to EN55015, En61000-3-2 Class C ( ?60% load) ; EN61000-3-3 |
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A |
Hold up Time | 16ms/230VAC - - -16ms/115VAC at full load |
Industry Aliases | new |
Input Voltage | 90~305VAC |
Inrush Current (Typ.) | COLD START 55A (twidth=270?S measured at 50% lpeak) at 230VAC |
Isolation Resistance | I/P - O/P : 100M Ohms / 500VDC / 25?C / 70% RH |
Load Regulation | ?2.0% |
MTBF | 396.7Khrs min. MIL-HDBK-217F (25?C) |
Number of Outputs | 1 |
Output Rated Current | 1.25A |
Output Voltage | 48V |
Over Current | 95 ~ 108% |
Over Temperature | 90?C?10?C (RTH2) |
Over Voltage | 15~17V |
Packing | 0.45Kg; 32pcs / 15.4Kg / 0.93CUFT |
Power Factor (Typ.) | PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) |
Safety Standards | UL870, CSA C22.2 No. 250.0-08(Except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 |
Setup, Rise Time | 1000ms, 80ms / 115VAC at full load ---- 1000ms, 80mas / 230VAC |
Short Circuit Protection | Hiccup mode, recovers automatically after fault condition is removed. |
Storage Temp., Humidity | -40 ~ +80?C, 10 ~ 95% RH |
Temp. Coefficient | ?0.03%/?C (0 ~ 50?C) |
Vibration | 10 ~ 500Hz, 5G 12min. / 1cycle, period for 72min. each along X, Y, Z axes |
Voltage Range | 90~305VAC 127~431VDC |
Wattage | 60 |
Withstand Voltage | I/P - O/P : 3.75KVAC |
Working Humidity | 20 ~ 95% RH non-condensing |
Working Temp. | -40 ~ +70?C (Refer to "Derating Curve") |