AC Current Accuracy | +/-2.0% + 5 Digits |
AC Current Measurement Resolution | 0.1 A |
AC Response, AC Response Calculation | TRMS |
AC Voltage Measurement Resolution | 0.1 V |
Audible Continuity, Auto Power Off, Auto Ranging, Batteries Included, Battery Access, Data Hold, Dustproof, Non-Contact Voltage Detector, Waterproof | Yes |
Basic AC Current Accuracy | +/-3.0% |
Basic AC Voltage Accuracy, Basic DC Voltage Accuracy | +/-1.5% |
Basic DC Current Accuracy, Resistance Measurement Accuracy | +/-1.0% |
Battery Chemistry | Alkaline |
Battery Size, Battery Type | AA |
Bluetooth Compatible, Calibration Certificate, Calibration Certificate Included, Current Leakage Testing, Intrinsically Safe, Removable Screen, Thermal Imaging | No |
Calibration Frequency | 50 to 60 Hz |
Capacitance Measurement Accuracy | +/-1.9% |
Capacitance Measurement Resolution | 1 uF |
Capacitance, Maximum Capacitance Measurement | 1,000 uF |
Clamp Meter Jaw Style | Split |
Country of Origin (subject to change) | Taiwan, Province of China |
Counts, Instrument Counts | 4,000 |
Data Logging_BROAD | Data Logging |
DC Current Measurement Resolution | 0.1 uA |
DC Voltage Measurement Resolution | 1 V |
Digital/Analog | Digital |
Display | Reverse Black LCD |
Display Type | LCD |
Dustproof_BROAD | Dustproof |
Features | Data Logging, Dustproof, Waterproof |
Features Filter_Background | 2206-20 Yes |
Features_Table | Dustproof; Waterproof; Data Logging |
Frequency Measurement Accuracy | +/-2.0% |
Includes | Batteries, Instructions, Test Leads |
Instrument Safety Rating | CAT III 1000V; CAT IV 600V |
IP Rating | IP54 |
Item | Digital Clamp Meter |
Jaw Capacity | 0.6 in (15 mm) |
Jaw Style | Open-Jaw |
Manufacturers Warranty Length | 5 yr |
Max. AC Amps | 1 |
Max. AC Volts, Max. DC Volts, Maximum AC Voltage Measurement, Maximum DC Voltage Measurement | 1,000 V |
Max. DC Amps | 1000micron A |
Max. Ohms | 40 |
Maximum AC Current Measurement | 200 A |
Maximum DC Current Measurement | 600 uA |
Maximum Operating Temperature | 752 Degrees F |
Maximum Resistance Measurement | 40 megaohm |
Minimum Operating Temperature | -40 Degrees F |
Operating Temp. | 14 Degrees to 122 Degrees F |
Overall Height | 8 in |
Parameters Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K) |
Promotion Restriction | Not eligible for promotion |
Resistance Measurement Resolution | 0.01 microohm |
Safety Rating | Cat IV 600V |
Safety Rating_Background | 2206-20 ; CAT III 1000V, 2206-20 ; CAT IV 600V |
Special Features | HVAC/R |
Temp. Range | -40 Degrees to 752 Degrees F |
Thermometer Type | Type K Thermocouple |
Waterproof_BROAD | Waterproof |