| AC Current Accuracy | +/-2.0% + 5 Digits |
| AC Current Measurement Resolution | 0.1 A |
| AC Response, AC Response Calculation | TRMS |
| AC Voltage Measurement Resolution | 0.1 V |
| Audible Continuity, Auto Power Off, Auto Ranging, Batteries Included, Battery Access, Data Hold, Dustproof, Non-Contact Voltage Detector, Waterproof | Yes |
| Basic AC Current Accuracy | +/-3.0% |
| Basic AC Voltage Accuracy, Basic DC Voltage Accuracy | +/-1.5% |
| Basic DC Current Accuracy, Resistance Measurement Accuracy | +/-1.0% |
| Battery Chemistry | Alkaline |
| Battery Size, Battery Type | AA |
| Bluetooth Compatible, Calibration Certificate, Calibration Certificate Included, Current Leakage Testing, Intrinsically Safe, Removable Screen, Thermal Imaging | No |
| Calibration Frequency | 50 to 60 Hz |
| Capacitance Measurement Accuracy | +/-1.9% |
| Capacitance Measurement Resolution | 1 uF |
| Capacitance, Maximum Capacitance Measurement | 1,000 uF |
| Clamp Meter Jaw Style | Split |
| Country of Origin (subject to change) | Taiwan, Province of China |
| Counts, Instrument Counts | 4,000 |
| Data Logging_BROAD | Data Logging |
| DC Current Measurement Resolution | 0.1 uA |
| DC Voltage Measurement Resolution | 1 V |
| Digital/Analog | Digital |
| Display | Reverse Black LCD |
| Display Type | LCD |
| Dustproof_BROAD | Dustproof |
| Features | Data Logging, Dustproof, Waterproof |
| Features Filter_Background | 2206-20 Yes |
| Features_Table | Dustproof; Waterproof; Data Logging |
| Frequency Measurement Accuracy | +/-2.0% |
| Includes | Batteries, Instructions, Test Leads |
| Instrument Safety Rating | CAT III 1000V; CAT IV 600V |
| IP Rating | IP54 |
| Item | Digital Clamp Meter |
| Jaw Capacity | 0.6 in (15 mm) |
| Jaw Style | Open-Jaw |
| Manufacturers Warranty Length | 5 yr |
| Max. AC Amps | 1 |
| Max. AC Volts, Max. DC Volts, Maximum AC Voltage Measurement, Maximum DC Voltage Measurement | 1,000 V |
| Max. DC Amps | 1000micron A |
| Max. Ohms | 40 |
| Maximum AC Current Measurement | 200 A |
| Maximum DC Current Measurement | 600 uA |
| Maximum Operating Temperature | 752 Degrees F |
| Maximum Resistance Measurement | 40 megaohm |
| Minimum Operating Temperature | -40 Degrees F |
| Operating Temp. | 14 Degrees to 122 Degrees F |
| Overall Height | 8 in |
| Parameters Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K) |
| Promotion Restriction | Not eligible for promotion |
| Resistance Measurement Resolution | 0.01 microohm |
| Safety Rating | Cat IV 600V |
| Safety Rating_Background | 2206-20 ; CAT III 1000V, 2206-20 ; CAT IV 600V |
| Special Features | HVAC/R |
| Temp. Range | -40 Degrees to 752 Degrees F |
| Thermometer Type | Type K Thermocouple |
| Waterproof_BROAD | Waterproof |