1800 Series Attachable Loop-Powered Digital Indicators | NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. |
Accuracy | Class B + (0.5 % Best Fit Straight Line (BFSL)) |
Additional Information | Quick response timeAlso available with our 1800 Series attachable loop indicator (see options & accessories below)CE compliant to suppress RFI, EMI, and ESD |
Ambient Temperature Range | -40 to 185 |
Application | Water systemsStorage tanksIndustrial machinery and machine toolsHVAC systemsRefrigeration systems |
Approximate Weight | 4 |
Category | 800 Series Platinum Resistance Temperature Transmitters |
Connection Size | 1/2 |
Connection Type | Male National Pipe Thread (MNPT) |
Electrical Connection | Hirschmann (DIN EN 175301-803 Form A) |
Electrical Protection | Reverse polarity, over-voltage and short circuit protection |
Environmental Rating | Ingress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529)) |
Housing material | 316 Stainless Steel |
Industry Standards/Certifications | European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Request for Information (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Load Limitations | <=(VPower - 10)/0.020 Amp for 4 mA to 20 mA output<=5000 ? for 1 Vdc to 5 Vdc output<=10,000 ? for 0 Vdc to 10 Vdc output<=4500 ? for 0.5 Vdc to 4.5 Vdc output |
Measuring Element | Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751)) |
Note | Thermowells are recommended for pressure, corrosive fluids and high velocity applications. |
Operating Pressure [Max] | 725 |
Operating Temperature [Max] | 20 |
Operating Temperature [Min] | 0 |
Output | [0.30 + 0.005 ltl] C0.5% Full Scale |
Output Signal | 0 Vdc to 10 Vdc, 3-Wire |
Power Supply | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire)10 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire)14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Price: | $344.60 |
Related Items | 50-090-304-SS, 9 in. Stem Length Thermowell|75-090-304-SS, 9 in. Stem Length Thermowell|75-090-316-SS, 9 in. Stem Length Thermowell |
SchemaID | 105023 |
Seal Material | 316 Stainless Steel |
Sensing Temperature [Max] | 85 |
Sensing Temperature [Min] | -40 |
Sensor Diameter | 6 |
Sensor Length | 9 |
Sensor Protection | Burnout protected from 3.3 mA to 23 mA |
Series | 800 |
Standard Temperature Ranges | -40 to 120|50 to 400 |
Syndication | 1 |
Thermowells | Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. |
Type | Transmitter |
Unit | 1 |