<p> Ambient humidity (Operating) | 5 to 85 %RH </p> </td> |
<p> Ambient temperature (Operating) | -<wbr>25 to 40 ? </p> </td> |
<p> Applicable standard | (UL) UL508, (CSA) C22.2 No.0, No.14, ?TUV? EN61810-<wbr>1, ?SEV? 98.5 50071.02 </p> </td> |
<p> Coil ratings | 110 VAC 9.9 mA ?50 Hz?, 110 VAC 8.4 mA ?60 Hz?, 120 VAC 10.8 mA ?50 Hz?, 120 VAC 9.2 mA ?60 Hz? </p> </td> |
<p> Contact rated load | 110 VAC 10 A (Resistive load (cos phi = 1))<br> 110 VAC 7.5 A (Inductive load (cos phi = 0.4))<br> 24 VDC 10 A (Resistive load)<br> 24 VDC 5 A (Inductive load (L/R = 7 ms)) </p> </td> |
<p> Contact Type | DPDT </p> </td> |
<p> Max. voltage | 110% (of rated voltage) </p> </td> |
<p> Maximum switching current: AC: 10 A,DC | 10 A </p> </td> |
<p> Maximum switching power: AC: 1100 VA ?Resistive load (cos phi = 1)?<br> AC: 825 VA ?Inductive load (cos phi = 0.4)?<br> DC: 240 VA ?Resistive load?<br> DC | 120 VA ?Inductive load (L/R = 7 ms)? </p> </td> |
<p> Model | LY2N </p> </td> |
<p> Mounting Style | Socket </p> </td> |
<p> Operating time (set time) 25ms | </p> </td> |
<p> Product classification | Monostable relays<br> Built-<wbr>in LED indicator type </p> </td> |
<p> Protective structure | Closed type (cover) </p> </td> |
<p> Release time (Reset time) | 25 ms </p> </td> |
<p> Termination Style | Plug Pin </p> </td> |
<p> Maximum switching voltage | 250 VAC,125 VDC </p> </td> |