[Ui] Rated Insulation Voltage | 575 V UL 508 |
Adjustable Range On Rising Pressure | 65-200 psi |
Ambient Air Temperature For Operation, Ambient Air Temperature For Storage | -33-257 ?F |
Approximate Adjustable Differential | 20-40 psi |
Cable Entry Number | 3 knock-outs for 1/2" conduit UL 508 |
California Proposition 65 : WARNING: This product can expose you to chemicals including | Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Circularity Profile | ENVEOLI111210EN |
Contacts Type And Composition | 2 NC, snap action, DPST-DB, Form YY |
Controlled Fluid | air -22-257 ?F) || fresh water -22-257 ?F) |
Depth | 3.88 in |
Destruction Pressure | 300 psi |
Electrical Circuit Type | power circuit |
Electrical Connection | screw-clamp terminals 10 AWG || screw-clamp terminals 5.261 mm? |
Electrical Durability | 100000 cycles 10 cyc/mn |
Environmental Disclosure | ENVPEP111211EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Factory Modification | 2-way pressure release valve |
Fluid Connection Type | 0.375 inch NPSF internal UL 508 |
Height | 5.4 in |
Ip Degree Of Protection | IP20 conforming to IEC 60529 |
Local Display | without |
Material | polypropylene Cover || noryl thermoplastic resin or equivalent Cover |
Materials In Contact With Fluid | zinc plated steel or equivalent flange || nitrile (Buna-N) or equivalent rubber diaphragm |
Maximum Operating Rate | 10 cyc/mn |
Mechanical Durability | 300000 cycles |
Mercury Free, Rohs Exemption Information | Yes |
Motor Power Kw | 1.5 kW 2 hp)115 V AC, 1 phase || 2.2 kW 3 hp)115 V AC, 3 phase || 2.2 kW 3 hp)230 V AC, 1 phase || 0.75 kW 1 hp)115 V DC || 0.75 kW 1 hp)230 V DC || 3.75 kW 5 hp)230 V AC, 3 phase || 3.7 kW 5 hp)460 V AC, 1 phase || 3.7 kW 5 hp)460 V AC, 3 phase || 3.7 kW 5 hp)575 V AC, 1 phase || 3.7 kW 5 hp)575 V AC, 3 phase |
Nema Degree Of Protection | NEMA 1 UL 50 |
Net Weight | 2.25 lb(US) |
Operating Position | any position |
Pressure Actuator | diaphragm |
Pressure Sensor Name | 9013GH |
Pressure Sensor Size | 200 psi 40-170 psi) |
Pressure Sensor Type | electromechanical pressure switch |
Pressure Switch Type Of Operation | regulation between 2 thresholds |
Product Certifications | CSA file LR25490 || UL listed file E12158 |
Product Specific Application | control electrically driven water pumps and air compressors |
Protective Treatment | none |
Quantity Per Set | 1 |
Range Of Product | Square D Pumptrol |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Repeat Accuracy | +/- 3 % |
Scale Type | adjustable differential |
Setting | internal |
Short-Circuit Protection | 20 A cartridge fuse gG |
Standards | NSF ANSI 372 || UL 508 || CE |
Sustainable Offer Status | Green Premium product |
Terminal Block Type | 4 terminals |
Terminals Description Iso N?1 | L1-T1 || L2-T2 |
Type Of Packing | individual |
Value Of Setting | 125...150 psi |
Warranty | 18 months |
Width | 4.19 in |