prev
SQUARE D ATV340D15N4E
SQUARE Dzoom
brand:
manufacturer:
Description:
Shop SQUARE D at Mayer. Variable speed drive - 15kW- 400V - 3 phases - ATV340 Ethernet

Attributes

Key Value
4 Quadrant Operation Possibletrue
[Us] Rated Supply Voltage380...480 V - 15...10 %
Acceleration And Deceleration Rampslinear adjustable separately from 0.01...9999 s || S, U or customized
Ambient Air Temperature For Operation-15-50 ?C without derating vertical position) || 50-60 ?C with derating factor vertical position)
Analogue Input Number2
Analogue Input TypeAI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits
Analogue Output Number2
Analogue Output Typesoftware-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits
Apparent Power28.3 kVA 480 V normal duty) || 29.7 kVA 480 V heavy duty)
Asynchronous Motor Control Profileoptimized torque mode || variable torque standard || constant torque standard
Base Load Current At High Overload32.0 A
Base Load Current At Low Overload39.0 A
Brake Chopper Integratedtrue
Braking To Standstillby DC injection
California Proposition 65 : WARNING: This product can expose you to chemicals includingLead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs RegulationX
Circularity ProfileENVEOLI1609006EN
Communication Port ProtocolModbus serial || Modbus TCP || EtherNet/IP
Connector Type3 RJ45
Continuous Output Current39 A 4 kHz normal duty || 32 A 4 kHz heavy duty
Data Format8 bits, configurable odd, even or no parity
Depth249.0 mm
Discrete Input Logic16 preset speeds
Discrete Input Number5
Discrete Input TypePTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable
Discrete Output Number2.0
Discrete Output Typeprogrammable output DQ1, DQ2 30 V DC 100 mA
Electrical Connectionscrew terminal 0.2...2.5 mm? control || screw terminal 6...25 mm? line side || screw terminal 6...25 mm? DC bus || screw terminal 4...25 mm? motor, control screw terminal 0.2...2.5 mm? AWG 24...AWG 12 || line side screw terminal 6...25 mm? AWG 8...AWG 3 || DC bus screw terminal 6...25 mm? AWG 8...AWG 3 || motor screw terminal 4...25 mm? AWG 10...AWG 3
Electromagnetic Compatibilityelectrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 ?s - 8/20 ?s surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6
Emc Filterclass C3 EMC filter integrated
Environmental Class (During Operation)class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Environmental DisclosureENVPEP1609006EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Height385.0 mm
Ip Degree Of ProtectionIP20
Line Current37.4 A 380 V normal duty) || 30.2 A 480 V normal duty) || 44.9 A 380 V heavy duty) || 35.7 A 480 V heavy duty), 44.9 A 380 V without line choke heavy duty) || 35.7 A 480 V without line choke heavy duty) || 42.4 A 380 V with external line choke normal duty) || 34.1 A 480 V with external line choke normal duty) || 45.5 A 380 V with external line choke heavy duty) || 36.0 A 480 V with external line choke heavy duty)
MarkingCE
Maximum Acceleration Under Shock Impact (During Operation)70 m/s? at 22 ms
Maximum Acceleration Under Vibrational Stress (During Operation)5 m/s? at 9...200 Hz
Maximum Deflection Under Vibratory Load (During Operation)1.5 mm at 2...9 Hz
Maximum Horse Power Rating25 hp normal duty || 20 hp heavy duty
Maximum Output Frequency0.599 kHz
Maximum Output Voltage480 V
Maximum Switching Currentrelay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2C resistive, cos phi = 1 5 A 250 V AC || relay output R2C resistive, cos phi = 1 5 A 30 V DC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Maximum Transient Current42.9 A 60 s normal duty) || 48 A 60 s heavy duty) || 52.7 A 2 s normal duty) || 58 A 2 s heavy duty)
Mercury FreeYes
Method Of Accessslave Modbus RTU || slave Modbus TCP
Minimum Switching Currentrelay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC
Motor Power Kw18.5 kW normal duty || 15 kW heavy duty
Motor Slip Compensationautomatic whatever the load || not available in permanent magnet motor law || can be suppressed || adjustable
Mounting Modecabinet mount
Net Weight9.5 kg
Nominal Output Current32.0 A
Nominal Switching Frequency4 kHz
Number Of Addresses1-247
Overvoltage Categoryclass III
Permitted Relative Humidity (During Operation)class 3K5 according to EN 60721-3
Phase3 phase
Physical Interface2-wire RS 485
Pollution Degree2 IEC 61800-5-1, 2
Power Dissipation In Wnatural convection 18 W 380 V 4 kHz heavy duty) || forced convection 346 W 380 V 4 kHz heavy duty) || natural convection 21 W 380 V 4 kHz normal duty) || forced convection 411 W 380 V 4 kHz normal duty)
Product CertificationsUL || CSA || T?V || EAC || CTick
Product Or Component Typevariable speed drive
Product Specific Applicationmachine
Prospective Line Isc22 kA
Protection Typethermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent between motor phases drive || short-circuit between motor phase and earth drive || short-circuit between motor phases drive || motor phase loss drive || DC Bus overvoltage drive || line supply overvoltage drive || line supply undervoltage drive || input supply loss drive || exceeding limit speed drive || break on the control circuit drive
Range Of ProductAltivar Machine ATV340
Reach RegulationReference contains Substances of Very High Concern above the threshold
Regulation Loopadjustable PID regulator
Relay Output Number2
Relay Output Typerelay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles
Rohs Exemption InformationYes
StandardsIEC 61800-3 || IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C
Supply Frequency50...60 Hz +/- 5 %
Sustainable Offer StatusGreen Premium product
Switching Frequency2...16 kHz adjustable || 7...16 kHz with derating factor
Synchronous Motor Control Profilereluctance motor || permanent magnet motor
Transmission FrameRTU
Transmission Rate4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Type Of Polarizationno impedance
UpgradeabilityUpgraded components available
Variantstandard version
Volume Of Cooling Air128.0 m3/h
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Width180.0 mm
With Safety Function Safe Brake Management (Sbc/Sbt)true
With Safety Function Safe Direction (Sdi)false
With Safety Function Safe Operating Stop (Sos)false
With Safety Function Safe Position (Sp)false
With Safety Function Safe Programmable Logicfalse
With Safety Function Safe Speed Monitor (Ssm)false
With Safety Function Safe Stop 1 (Ss1)true
With Safety Function Safe Torque Off (Sto)true
With Safety Function Safely Limited Position (Slp)false
With Safety Function Safely Limited Speed (Sls)true
With Sft Fct Safe Stop 2 (Ss2)false