| 4 Quadrant Operation Possible | true |
| [Us] Rated Supply Voltage | 380...480 V - 15...10 % |
| Acceleration And Deceleration Ramps | linear adjustable separately from 0.01...9999 s || S, U or customized |
| Ambient Air Temperature For Operation | -15-50 ?C without derating vertical position) || 50-60 ?C with derating factor vertical position) |
| Analogue Input Number | 2 |
| Analogue Input Type | AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits |
| Analogue Output Number | 2 |
| Analogue Output Type | software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits |
| Apparent Power | 28.3 kVA 480 V normal duty) || 29.7 kVA 480 V heavy duty) |
| Asynchronous Motor Control Profile | optimized torque mode || variable torque standard || constant torque standard |
| Base Load Current At High Overload | 32.0 A |
| Base Load Current At Low Overload | 39.0 A |
| Brake Chopper Integrated | true |
| Braking To Standstill | by DC injection |
| California Proposition 65 : WARNING: This product can expose you to chemicals including | Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
| China Rohs Regulation | X |
| Circularity Profile | ENVEOLI1609006EN |
| Communication Port Protocol | Modbus serial || Modbus TCP || EtherNet/IP |
| Connector Type | 3 RJ45 |
| Continuous Output Current | 39 A 4 kHz normal duty || 32 A 4 kHz heavy duty |
| Data Format | 8 bits, configurable odd, even or no parity |
| Depth | 249.0 mm |
| Discrete Input Logic | 16 preset speeds |
| Discrete Input Number | 5 |
| Discrete Input Type | PTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable |
| Discrete Output Number | 2.0 |
| Discrete Output Type | programmable output DQ1, DQ2 30 V DC 100 mA |
| Electrical Connection | screw terminal 0.2...2.5 mm? control || screw terminal 6...25 mm? line side || screw terminal 6...25 mm? DC bus || screw terminal 4...25 mm? motor, control screw terminal 0.2...2.5 mm? AWG 24...AWG 12 || line side screw terminal 6...25 mm? AWG 8...AWG 3 || DC bus screw terminal 6...25 mm? AWG 8...AWG 3 || motor screw terminal 4...25 mm? AWG 10...AWG 3 |
| Electromagnetic Compatibility | electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 ?s - 8/20 ?s surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6 |
| Emc Filter | class C3 EMC filter integrated |
| Environmental Class (During Operation) | class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3 |
| Environmental Disclosure | ENVPEP1609006EN |
| Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Height | 385.0 mm |
| Ip Degree Of Protection | IP20 |
| Line Current | 37.4 A 380 V normal duty) || 30.2 A 480 V normal duty) || 44.9 A 380 V heavy duty) || 35.7 A 480 V heavy duty), 44.9 A 380 V without line choke heavy duty) || 35.7 A 480 V without line choke heavy duty) || 42.4 A 380 V with external line choke normal duty) || 34.1 A 480 V with external line choke normal duty) || 45.5 A 380 V with external line choke heavy duty) || 36.0 A 480 V with external line choke heavy duty) |
| Marking | CE |
| Maximum Acceleration Under Shock Impact (During Operation) | 70 m/s? at 22 ms |
| Maximum Acceleration Under Vibrational Stress (During Operation) | 5 m/s? at 9...200 Hz |
| Maximum Deflection Under Vibratory Load (During Operation) | 1.5 mm at 2...9 Hz |
| Maximum Horse Power Rating | 25 hp normal duty || 20 hp heavy duty |
| Maximum Output Frequency | 0.599 kHz |
| Maximum Output Voltage | 480 V |
| Maximum Switching Current | relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2C resistive, cos phi = 1 5 A 250 V AC || relay output R2C resistive, cos phi = 1 5 A 30 V DC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
| Maximum Transient Current | 42.9 A 60 s normal duty) || 48 A 60 s heavy duty) || 52.7 A 2 s normal duty) || 58 A 2 s heavy duty) |
| Mercury Free | Yes |
| Method Of Access | slave Modbus RTU || slave Modbus TCP |
| Minimum Switching Current | relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC |
| Motor Power Kw | 18.5 kW normal duty || 15 kW heavy duty |
| Motor Slip Compensation | automatic whatever the load || not available in permanent magnet motor law || can be suppressed || adjustable |
| Mounting Mode | cabinet mount |
| Net Weight | 9.5 kg |
| Nominal Output Current | 32.0 A |
| Nominal Switching Frequency | 4 kHz |
| Number Of Addresses | 1-247 |
| Overvoltage Category | class III |
| Permitted Relative Humidity (During Operation) | class 3K5 according to EN 60721-3 |
| Phase | 3 phase |
| Physical Interface | 2-wire RS 485 |
| Pollution Degree | 2 IEC 61800-5-1, 2 |
| Power Dissipation In W | natural convection 18 W 380 V 4 kHz heavy duty) || forced convection 346 W 380 V 4 kHz heavy duty) || natural convection 21 W 380 V 4 kHz normal duty) || forced convection 411 W 380 V 4 kHz normal duty) |
| Product Certifications | UL || CSA || T?V || EAC || CTick |
| Product Or Component Type | variable speed drive |
| Product Specific Application | machine |
| Prospective Line Isc | 22 kA |
| Protection Type | thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent between motor phases drive || short-circuit between motor phase and earth drive || short-circuit between motor phases drive || motor phase loss drive || DC Bus overvoltage drive || line supply overvoltage drive || line supply undervoltage drive || input supply loss drive || exceeding limit speed drive || break on the control circuit drive |
| Range Of Product | Altivar Machine ATV340 |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Regulation Loop | adjustable PID regulator |
| Relay Output Number | 2 |
| Relay Output Type | relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles |
| Rohs Exemption Information | Yes |
| Standards | IEC 61800-3 || IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C |
| Supply Frequency | 50...60 Hz +/- 5 % |
| Sustainable Offer Status | Green Premium product |
| Switching Frequency | 2...16 kHz adjustable || 7...16 kHz with derating factor |
| Synchronous Motor Control Profile | reluctance motor || permanent magnet motor |
| Transmission Frame | RTU |
| Transmission Rate | 4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s |
| Type Of Polarization | no impedance |
| Upgradeability | Upgraded components available |
| Variant | standard version |
| Volume Of Cooling Air | 128.0 m3/h |
| Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Width | 180.0 mm |
| With Safety Function Safe Brake Management (Sbc/Sbt) | true |
| With Safety Function Safe Direction (Sdi) | false |
| With Safety Function Safe Operating Stop (Sos) | false |
| With Safety Function Safe Position (Sp) | false |
| With Safety Function Safe Programmable Logic | false |
| With Safety Function Safe Speed Monitor (Ssm) | false |
| With Safety Function Safe Stop 1 (Ss1) | true |
| With Safety Function Safe Torque Off (Sto) | true |
| With Safety Function Safely Limited Position (Slp) | false |
| With Safety Function Safely Limited Speed (Sls) | true |
| With Sft Fct Safe Stop 2 (Ss2) | false |