[Uimp] Rated Impulse Withstand Voltage | 0.5 kV DC |
[Us] Rated Supply Voltage | 24 V DC SELV 17-33 V) |
Adjustable Range Of Switching Point On Falling Pressure | -0.97--0.05 bar || -14.1--0.73 psi || -97-5 kPa |
Adjustable Range Of Switching Point On Rising Pressure | -1--0.08 bar || -14.5--1.16 psi || -100--8 kPa |
Ambient Air Temperature For Operation | -20-80 ?C |
Ambient Air Temperature For Storage | -40-80 ?C |
Analogue Output Function | 4...20 mA |
California Proposition 65 : WARNING: This product can expose you to chemicals including | Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Contacts Type And Composition | NO/NC programmable |
Controlled Fluid | fresh water 0-80 ?C) || air -20-80 ?C) || hydraulic oil -20-80 ?C) || refrigeration fluid -20-80 ?C) |
Depth | 42 mm |
Destruction Pressure, Maximum Permissible Accidental Pressure | 43 psi || 3 bar || 300 kPa |
Device Short Name | XMLR |
Discrete Output Type | solid state NPN, NO/NC programmable |
Display Response Time Type | fast 50 ms || normal 200 ms || slow 600 ms |
Display Type | 4 digits 7 segments |
Drift Of The Sensitivity | +/- 0.03 % of measuring range/?C |
Drift Of The Zero Point | +/- 0.1 % of measuring range/?C |
Electrical Connection | male connector M12, 4 pins |
Electromagnetic Compatibility | susceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 || immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 || surge immunity test 1 kV EN/IEC 61000-4-5 || electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 || electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2 |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Fluid Connection Type | 1/4" - 18 NPT (female) |
Front Material | polyester |
Height | 100 mm |
Housing Material | polyacrylamide || 316L stainless steel |
Ip Degree Of Protection | IP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529 |
Local Signalling | for light ON when switch is actuated 1 LED (yellow) |
Marking | CE |
Materials In Contact With Fluid | ceramic || 316L stainless steel || fluorocarbon FKM (Viton) |
Maximum Delay First Up | 300 ms |
Maximum Switching Current | 250 mA |
Maximum Voltage Drop | 2 V |
Mechanical Durability | 10000000 cycles |
Mercury Free, Reach Free Of Svhc, Rohs Exemption Information | Yes |
Minimum Differential Travel | 0.43 psi || 3 kPa || 0.03 bar |
Net Weight | 0.212 kg |
Operating Position | any position, but disposals can falsified the measurement in case of upside down mounting |
Pressure Sensor Size | -1 bar || -14.5 psi |
Pressure Sensor Type | pressure transmitter |
Pressure Switch Type Of Operation | pressure transmitter with 1 switching output |
Product Certifications | cULus || EAC |
Product Or Component Type | electronic pressure sensors |
Protection Type | short-circuit protection || reverse polarity || overvoltage protection || overload protection |
Range Of Product | OsiSense XM |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
Scale Type | fixed differential |
Shock Resistance | 50 gn EN/IEC 60068-2-27 |
Standards | EN/IEC 61326-2-3 || UL 61010-1 |
Time Delay Range | 0...50 s in steps of 1 second |
Type Of Output Signal | analogue + discrete |
Vibration Resistance | 20 gn 10-2000 Hz)EN/IEC 60068-2-6 |
Width | 41 mm |