| Key ^ | Value |
|---|---|
| Accuracy | ?0.075% F.S. |
| Adjustable Range | -14.5 to 1500psi |
| Agency Approval | CSA Class I Div I |
| Diaphragm Materials | Hastelloy C |
| Enclosure Rating | NEMA 4X (IP67) |
| Insulation Resistance | ?20 M ? at 100VDC |
| Measuring Range | 5 to 10000psig (5 to 1500psig) |
| Mounting Position Effect | Apply to any position. A max value lower than 1.6 w.c. (400 Pa) can be corrected by zero zero-clearing function |
| Output Signal | 4 mA to 20 mA with HART?Communication |
| Process Connection | 1/2? MNPT |
| Stability | ?0.2 % URL/5 year |
| Testing Standard | IEC60770 |
| Weight | 3.43 lb (1.55kg) |
| Wetted Material | 316 L SS and Hastelloy C |
| Working Humidity | 5 to 100% |