Attributes

Key Value
Agency ComplianceETL Listed to UL378 and.
Airflow @ 0.000 in SP110 cfm
Airflow at Temperature10 cfm @ 70 Degrees F, .
Amps1.26
ApplicationUsed for Side Wall Vent.
Blower TypeSidewall Power Venter
BtuH Input25-100
CFM @ 0.000-In. SP110 110 110 110
CFM @ 0.500-In. SP85 68 57 40
CFM @ 0.700-In. SP72 10 - -
CFM @ 1.000-In. SP10 - - -
CFM @ 1.40-In. SP- - - -
CFM @ 270 Deg. (F)-
CFM @ 390 Deg. (F)-
CFM @ 530 Deg. (F)-
Construction MaterialAluminized Steel Housin.
Country of Origin (subj.United States
Current1.26 A
Cut Out Required-
Depth (In.)7 in
Duct Temp. Deg. (F)70,300,400,500
For Appliance TypeBoilers, Furnaces, Unit.
For Fuel TypeLP, Natural Gas, Oil
For Maximum Pipe Length100 ft
For Pipe Diameter4 in
For Use WithPower Venter
Heater Btu Input @ 270 .Not Applicable
Heater Btu Input @ 390 .Not Applicable
Heater Btu Input @ 530 .Not Applicable
Height (In.)7 7/8 in
Housing MaterialSteel
Housing Material FinishAluminum Plated
IncludesAdjustable Damper, Fan .
Includes MotorYes
Inlet and Outlet Dia. (.4
Inlet Diameter4 in
ItemInduced Draft Blower
MarketCommercial, Residential
Max. Pipe Length 300100
Max. Pipe Length 400100
Max. Pipe Length 500100
Maximum Heat Input100 MBtuH
Maximum Heater BTU Inpu.125,000 BtuH
Maximum Heater BTU Inpu.75,000 BtuH
Maximum Motor Speed3,000 RPM
Maximum Static Pressure1 3/8 in wc
Maximum Vent Pipe Diame.4 in
Nameplate Voltage115V AC
Nominal Voltage115V AC
Outlet Diameter4 in
Outlet HeightNot Applicable
Outlet ShapeRound
Outlet WidthNot Applicable
Overall Depth7 5/8 in
Overall Height9 5/8 in
Overall HxWxD9 5/8 in x 9 7/8 in x 7.
Overall Width9 7/8 in
Power Consumption95 W
RemarksView Catalog Page for S.
Replaces-
SP @ 270 Deg. (F)Not Applicable
SP @ 390 Deg. (F)Not Applicable
SP @ 530 Deg. (F)Not Applicable
StandardscETL Listed
TypeHigh Temperature
Voltage115
Watts95 W
Width (In.)10 1/4 in
prev