Aux. Switch Off Time (Sec.) | - |
Aux. Switch On Time (Sec.) | - |
Control Volts | 24 |
Country of Origin (subject to change) | Mexico |
Depth (In.) | 1-5/8 |
Full Load Amps @ 120VAC | 14 |
Full Load Amps @ 240VAC | 7 |
Full Load Amps @ 480V | 3 |
Full Load Amps @ 600V | - |
Height (In.) | 1-1/2 |
Includes | Double Quick-connect Terminals for Combination Loads |
Item | Electric Sequencer |
Locked Rotor Amps @ 120V | 72 |
Locked Rotor Amps @ 240V | 42 |
Locked Rotor Amps @ 480V | 18 |
Locked Rotor Amps @ 600V | - |
Main Switch Off Time (Sec.) | 1 to 30 |
Main Switch On Time (Sec.) | 30 to 90 |
Number of Switches | 1 |
Number of Timings | 1 |
Off Time (Seconds) | 1 to 30 |
On Time (Seconds) | 30 to 90 |
Pilot Duty 120/480V (VA) | 125 |
Resistive Amps @ 120V | 25 |
Resistive Amps @ 240V | 25 |
Resistive Amps @ 277V | - |
Resistive Amps @ 480V | 12.5 |
Resistive Amps @ 600V | - |
Therm-o-Disc Model No. | 15SH1309572 |
Type | Strip Heat And/Or Blower Fan In Heat Pumps And Electric Furnaces |
Width (In.) | 1-5/8 |