mpn
02-391790
brand
name: DANFOSS
manufacturer
name: DANFOSS
Attributes
Key
Value
Actuation identification
Solenoid A, Solenoid B
Actuation type
Solenoid Operated
Actuator identification
Flag with Standard Buil.
Application
Die casting & foundry, .
Body material7
Gray Iron
Build orientation
Solenoid `B` at port `A.
Build type
Spring centered
Coil rating
220 Volt AC 50 Hz/240 V.
Coil type
ISO 4400 mounting
Design code11
10
Eccn
EAR99
Electrical connector
ISO 4400 (Din 43650) Co.
Flow rate12
115 litre per minute
Fluid cleanliness
19/17/14 micron
Fluid compatibility13
Petroleum Oils
Function
Directional Control Val.
Icc2
IV Directional Control .
Interface
ISO4401-AC-05-4-A/NFPA .
Leakage
Standard
Light
No
Manual override
Plain
Model Code
DG4V4-01-0C-M-U-D5-10
Performance
Standard
Pressure rating
315 bar
Product height
4.31
Product height uom
inch
Product length
9.38
Product length uom
inch
Product trade name
DG4V4-01 10 Design
Product weight
13.20
Product weight uom
pound
Product width
2.84
Product width uom
inch
Seal material16
Buna-N
Size
D05
Special features17
None
Spool center condition
A Port and Double Offse.
Spring arrangement
C
Stage
Single Stage
Sub brand
Vickers
Tank port rating
100 bar
Valve mount type
Subplate/manifold mount.
Wattage
30 watt
Working temperature max
50 degree Celsius
Working temperature min
20 degree Celsius