Johnson Controls A19ABC-37C

B07T189WTJ

Johnson Controls A19ABC-37C Remote Bulb Temperature Control Dial Range -30~100 Deg F Differential Min. 3 Deg F Max. 12 Deg F Capillary Length 10' Bulb OD 3/8 in. Length 4 in. SpeedT 22A 277

Johnson Controls A19ABC-37C Remote Bulb Temperature Control Dial Range -30~100 Deg F Differential Min. 3 Deg F Max. 12 Deg F Capillary Length 10zoom

Attributes

Key Value
Bulb Diameter1/2 in
Bulb Length4 in
Capillary Length120 in
Capillary Length/Bulb D.10 ft Capillary, 4 in x.
Changeover TypeManual
ColorGray
Compatible System TypeHot Water Heating Contr.
Contact Rating120V AC, 240V AC
Contact Rating Resistiv.22 A
Contact Rating Resistiv.22 A
Contact Rating Resistiv.22 A
Control Range-30 Degrees to 100 Degr.
Country of Origin (subj.United States, Mexico
Depth1 13/16 in
Differential3 Degrees to 12 Degrees.
Differential TypeAdjustable
Electrical Connection T.Hardwired, Screw Termin.
Enclosure ColorGray
Enclosure MaterialSteel
Enclosure NEMA RatingNEMA 1
Enclosure TypeGalvanized/Steel
Full Load Amps @ 120V AC16 A
Full Load Amps @ 120VAC16 A
Full Load Amps @ 240V AC8 A
Full Load Amps @ 240VAC8 A
Height4 3/8 in
IncludesRemote Sensing Bulb
Inductive Amps @ 120V16 A
Inductive Amps @ 208V9.2 A
Inductive Amps @ 240V8 A
ItemLine Volt Mechanical Ts.
Locked Rotor Amps @ 120V96 A
Locked Rotor Amps @ 240V48 A
Maximum Control Tempera.100 Degrees F
Minimum Control Tempera.-30 Degrees F
Mounting TypeFlat Surface
Number of Cooling Stages1
Number of Heating Stages1
Number of Poles1
Number of Relay Inputs1
Number of Relay Outputs1
Number of Switches1
Overall Depth1 3/4 in
Overall Height4 1/2 in
Overall Width2 1/4 in
Pilot Duty Contacts (VA)125 VA
Pilot Duty Rating125 VA @ 24 to 600V AC
Remote Sensing Bulb Inc.Yes
Remote Sensing Capabili.Yes
Resistive Amps @ 208V AC22 A
Resistive Amps @ 208VAC22 A
Sensing Bulb Dia.3/8 in
Sensing Bulb Length4 in
Sensor LocationRemote
Sensor TypeBulb
Stages1H/1C
StandardsUL E6688; CSA LR948/481.
Switch ActionOpen/Close on Rise
Switch TypeSPDT
Switch Type/ActionSPDT, Open/Close on Rise
Temp. Sensitivity+/-2 Degrees F
Temperature Control Ran.-30 Degrees to 100 Deg.
Temperature Differential3 Degrees to 12 Degree.
Temperature ScaleFahrenheit/Celsius
Temperature Sensitivity+/-2 Degrees F
Thermostat Control Range-30 Degrees to100 Degr.
Thermostat Heating/Cool.Heating/Cooling
Thermostat ItemLine Voltage Mechanical.
Thermostat ProgrammableNo
Thermostat Switch TypeSPDT
Thermostat Voltage120 to 277V AC
Voltage120/208/240VAC
Width2 1/8 in

All Prices

Img Seller Supplier SKU Min Price MOQ In Stock Lead Time Brand Weight Preferred Tier
thumbzoomNRI IndustrialD75095970.851In StockJOHNSON CONTROLS70.85 @ 1
ptacsolutions.com300000635120.821In StockJOHNSON CONTROLS120.82 @ 1
Grainger38Y060122.0189JOHNSON CONTROLS122.0 @ 1
thumbzoomZoroG7678335130.331In Stock26Johnson Controls130.33 @ 1
thumbzoomwaterpumpsnow.comA19ABC-37C156.21In StockJohnson2.0156.2 @ 1
thumbzoomNational Supply NetworkB476160173.141In StockJohnson Controls Inc173.14 @ 1
prev


As an Amazon Associate I earn from qualifying purchases.

1759738934.5358