Attributes

Key Value
Auxiliary OutputYes
CascadeYes
Connector TypeM12
Defined Area Height (mm)1200
Dimensions WxD (mm)36 x 45.2
Effective Aperture AngleType 4 Per IEC 61496-2
Electrical Safety ClassIII
End-to-End SensingNo
ESD SafeNo
External Monitoring Dev.1 or 2 Channel
Fault OutputNo
Fixed BlankingYes
Housing FinishYellow Polyester
Housing MaterialAluminum; Zinc; Acrylic
Integral MutingNo
IP RatingIP65
low-profileNo
Number of Pins (Receive.8
Operating Distance (m)0.1 - 18
Operating Temperature0 to +55 deg. C; RH 95%
Operating Voltage24 V dc +/- 15%
OSSD Rating24 V dc at 0.5 A each
Overall Length (mm)1270
PL RatingPle
Primary Housing MaterialAluminum
Recovery Time25-152 / 81-495
Reduced ResolutionYes
Resolution (mm)30
Response Time23
Safety LevelType 4
Scan CodeSelectable
Shock10g at 16ms (6000 cycle.
Short ProtectionYes
SIL RatingSIL3; CL3
Supply Current275 mA max.
System TypeReceiver
Test InputNo
Trip/Latch OutputSelectable
Vibration10-55 Hz at 0.35 mm