Key Value
Auxilary mounting padCD:SAE-C,14 teeth,4 bolt
Charge pressure setting24:24bar
Charging systemF:26 cc/rev
Control orifices03:P 0,81;TA+TB 1,3;A+B.
ControlsKP:EDC3,wp,14-85mA
Displacement limitation4:both sides
Endcap portstwin ports
FiltrationL:long filter
High pressure regulation1:A&B up to 450bar
High pressure setting a35:350bar
High pressure setting b35:350bar
Input shaftF1:spline,13 teeth,8/16
Model Code90R130-KP-1-CD-80-L-4-F.
Proposition 65Cancer and Reproductive.
Pth full pathDPS>High Power Closed C.
Series 90 pump type90R130
Special hardware featur.GBA:CP15+0,5