Attributes

Key Value
2...25 Hz?1.6 mm
25...100 Hz?4 g
AccuracyBetter than 0.05% of se.
ATEX 2014/34/EUDEKRA 15 ATEX 0058 X
back lightSelectable ON/OFF
back light colorSelectable white or red
Cable resistance per wi.5 ? (up to 50 ? per wir.
Calibration temperature20...28?C
Cold junction compensat.Constant, internal or e.
CSA70024231
Dimensions? 110 mm
EACTR-CU 020/2011
EAC Ex TR-CU 012/2011RU C-DK.GB08.V.01316
EMC2014/30/EU
EMC immunity influence< ?0.1% of span
EU RO Mutual Recognitio.MRA0000009
Extended EMC immunity: .< ?1% of span
FMFM16US0009X / FM16CA001.
HART protocol revisionsHART 7 and HART 5
IECExIECEx DEK 15.0039 X
INMETRODEKRA 15.0014 X
Input resistance10 M?
Isolation voltage, test.1.5 kVAC / 50 VAC
Linear resistance min...0 ?...7000 ?
Load (at current output)? (Vsupply - 10) / 0.02.
Load resistance, with b.? (Vsupply - 12) / 0.02.
Long-term stability, be.?0.1% of span / year
Max. offset50% of selected max. va.
Measurement range-800...+800 mV
Min. measurement range .2.5 mV
Min. signal range16 mA
NAMUR NE43 Upscale/Down.23 mA / 3.5 mA
NEPSIGYJ15.1336X, GYJ15.1337.
Number of digits5
Operating temperature-20?C to +85?C (with FK.
ProgrammingHART
Protection degreeIP54 / IP66 / IP68 / ty.
Relative humidity0...100% RH (condensing)
Response time (programm.1...60 s
RTD typePt50/100/200/500/1000; .
Screw terminal torque0.4 Nm
Sensor currentNom. 0.2 mA
Sensor error indicationProgrammable 3.5?23 mA
Signal / noise ratio> 60 dB
Signal dynamics, input22 bit
Signal dynamics, output16 bit
Signal range4?20 mA
SILHardware assessed for u.
Start-up time, transmit.Max. 5 s
Storage temperature-40?C to +85?C
Supply voltage, DC: Ex .10 (12 - with back ligh.
Supply voltage, DC: Oth.10 (12 - with back ligh.
Thermocouple typeB, E, J, K, L, N, R, S,.
Updating time440 ms
VibrationIEC 60068-2-6
Weight approx., aluminu.1.3 / 2.8 kg
Wire size0.13 x1.5 mm2 / AWG 26..