9 Mm Pitches | 6 |
[Ics] Rated Service Breaking Capacity | 25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2 |
[Ue] Rated Operational Voltage | 525 V AC 50/60 Hz UL 489 |
[Ui] Rated Insulation Voltage | 800 V IEC 60947-2 |
[Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947-2 |
Ambient Air Temperature For Operation | -25-70 ?C |
Ambient Air Temperature For Storage | -50-85 ?C |
Awg Gauge | AWG 14...AWG 2/0 aluminium/copper |
Breaking Capacity | 25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 10 kA 600Y/347 V AC 50/60 Hz UL 489 |
Breaking Capacity Code | D |
California Proposition 65 : WARNING: This product can expose you to chemicals including | DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Color | Gray RAL 7016) |
Connection Pitch | 27 mm |
Continuous Current Rating | 80 % |
Control Type | toggle |
Depth | 89 mm |
Device Application | distribution |
Device Short Name | BD 025 |
Electrical Connection | I-Line connection line || lugs load |
Electrical Durability | 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In |
Environmental Disclosure | ENVPEP1610005EN |
Eu Rohs Directive | Compliant |
Halogen Content Performance | Halogen free product |
Height | 137 mm |
Ik Degree Of Protection | IK07 IEC 62262 |
Ip Degree Of Protection | front cover IP40 IEC 60529 |
Line Rated Current | 25-25 A |
Local Signalling | presence of auxiliary contacts flag green) |
Mechanical Durability | 20000 cycles IEC 947-1 Annex K ed 5.2 |
Mercury Free, Pvc Free, Rohs Exemption Information | Yes |
Mounting Height | 76.2 mm |
Mounting Mode | I-Line |
Net Weight | 0.952 kg |
Network Frequency | 50/60 Hz |
Number Of Slots | 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) |
Phase Connection | BC |
Poles Description | 2P |
Pollution Degree | 3 IEC 60947-1 |
Product Certifications | UL || IEC || CCC || EAC || CSA || NOM |
Product Name | PowerPact B |
Product Or Component Type | circuit breaker |
Quality Labels | CE |
Quantity Per Set | set of 1 |
Range | PowerPact |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Standards | NEMA AB1 || EN/IEC 60947-5-1 || NMX J-266 || GB 14048.2 || CSA C22.2 No 5 || UL 489 || EN/IEC 60947-2 |
Suitability For Isolation | yes IEC 60947-2 |
Sustainable Offer Status | Green Premium product |
Tightening Torque | 3.6-4.4 N.m 2.5-6 mm? (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm? (AWG 8...AWG 2/0) |
Trip Unit Technology | thermal-magnetic |
Utilisation Category | category A |
Width | 54 mm |