Attributes

Key Value
[Ie] Rated Operational .3 A 240 V, AC-15, A600 .
[Ith] Conventional Free.10 A EN/IEC 60947-5-1
[Ui] Rated Insulation V.600 V 3)EN/IEC 60947-1
[Uimp] Rated Impulse Wi.6 kV EN/IEC 60947-1
[Us] Rated Supply Volta.24 V AC/DC 50/60 Hz
Ambient Air Temperature.-40-70 ?C
Ambient Air Temperature.-40-70 ?C
Bezel Materialchromium plated metal
Bulb Baseintegral LED
California Proposition .Lead and lead compounds.
China Rohs RegulationX
Circularity ProfileENVEOLI1808008EN
Contact Operationslow-break
Contacts Materialsilver alloy (Ag/Ni)
Contacts Type And Compo.1 NO + 1 NC
Contacts Usagestandard contacts
Current Consumption18 mA
Depth55 mm
Device Mountingbuilt-in
Device Presentationcomplete product
Device Short NameXB4F
Electrical Durability1000000 cycles, AC-15, .
Electrical Shock Protec.class I IEC 60536
Electromagnetic Emissionclass B IEC 55011
Environmental DisclosureENVPEP1808008EN
Eu Rohs DirectivePro-active compliance (.
Fixing Collar Materialzamak
Fixing Modeby screws 0.8 N.m
Head Typebuilt-in-flush
Height47 mm
Ik Degree Of ProtectionIK06 IEC 50102
Ip Degree Of ProtectionIP66 IEC 60529 || IP67 .
Light Sourceprotected LED
Mechanical Durability10000000 cycles
Mercury FreeYes
Mounting Diameter30.5 mm
Net Weight0.132 kg
Operating Force3.5 N NC changing elect.
Operating Travel1.5 mm NC changing elec.
Operator Additional Inf.with plain lens
Operator Profilegreen flush
Positive Openingwith EN/IEC 60947-5-1 a.
Product CertificationsUL Listed || CSA || CCC.
Product Or Component Ty.illuminated push-button
Protective TreatmentTH
Range Of ProductHarmony XB4
Reach Free Of SvhcYes
Reach RegulationFree of Substances of V.
Resistance To Electroma.10 V/m IEC 61000-4-3
Resistance To Electrost.6 kV on contact (on met.
Resistance To Fast Tran.2 kV IEC 61000-4-4
Resistance To High Pres.7000000 Pa 55 ?C 0.1 m
Rohs Exemption Informat.Yes
Sale Per Indivisible Qu.1
Service Life100000 h at rated volta.
Shape Of Screw Headcross Philips no 1 || c.
Shape Of Signaling Unit.round
Shock Resistance30 gn 18 ms) half sine .
Short-Circuit Protection10 A cartridge fuse gG .
Signalling Typesteady
StandardsCSA C22.2 No 14 || EN/I.
Supply Voltage Limits19.2-30 V DC || 21.6-26.
Surge Withstand1 kV IEC 61000-4-5
Sustainable Offer StatusGreen Premium product
Terminals Description I.(21-22)NC || (13-14)NO
Tightening Torque0.8-1.2 N.m EN 60947-1
Type Of Operatorspring return
Vibration Resistance5 gn 10-500 Hz)IEC 6006.
Warranty18 months
WeeeThe product must be dis.
Width36.6 mm
prev