Attributes

Key Value
[Ui] Rated Insulation V.300 VUL 508 || 400 V 3).
[Uimp] Rated Impulse Wi.4 kV IEC 60664 || 4 kV .
Ambient Air Temperature.-25-70 ?C
Ambient Air Temperature.-40-70 ?C
Body Materialzamak
Cable Composition9 x 0.34 mm?
Cable Length2 m
California Proposition .Diisononyl phthalate (D.
Circularity ProfileENVEOLI110612EN
Component NameXCSM
Contact Code DesignationB300, AC-15 (Ue = 240 V.
Contact Operationsnap action
Contacts Type And Compo.1 NC + 1 NC + 1 NO + 1 .
Depth34 mm
Designminiature
Electrical Connectionpre-cabled
Electrical Shock Protec.class I NF C 20-030 || .
Environmental DisclosureENVPEP110612EN
Eu Rohs DirectivePro-active compliance (.
Fixing Modeby the body
Head Materialzamak
Head Typerotary head
Height94-94 mm
Ik Degree Of ProtectionIK06 EN 50102
Ip Degree Of ProtectionIP66 conforming to IEC .
Materialmetal
Maximum Actuation Speed1.5 m/s
Maximum Resistance Acro.25 MOhm IEC 60255-7 cat.
Mechanical Durability10000000 cycles
Mercury FreeYes
Minimum Actuation Speed0.01 m/min
Minimum Torque For Trip.0.5 N.m
Net Weight0.21 kg
Number Of Poles4
Positive Openingwith NC contact
Positive Opening Minimu.0.1 N.m
Product CertificationsCSA || UL
Product Or Component Ty.safety limit switch
Protection Technologyplastic protective cove.
Protective TreatmentTC
Range Of ProductTelemecanique Safety sw.
Reach RegulationReference contains Subs.
Repeat Accuracy0.05 mm on the tripping.
Rohs Exemption Informat.Yes
Safety Levelcan reach category 4 wi.
Safety Reliability DataB10d = 50000000 value g.
Shock Resistance25 gn 18 ms IEC 60068-2.
Short-Circuit Protection6 A cartridge fuse gG (.
StandardsCSA C22.2 No 14 || EN 1.
Sustainable Offer StatusGreen Premium product
Switch Actuationby 30? cam
Type Of Approachlateral approach
Type Of Operatorsteel roller lever
Vibration Resistance5 gn 10-500 Hz)IEC 6006.
Warranty18 months
Width30 mm
prev