Attributes

Key Value
[Uimp] Rated Impulse Wi.0.5 kV
[Us] Rated Supply Volta.24 V DC 11.4-33 V)
Ambient Air Temperature.-15-85 ?C
Ambient Air Temperature.-40-85 ?C
Analogue Output Function0...10 V, 3 wires
California Proposition .Diisononyl phthalate (D.
Controlled Fluidair -15-125 ?C) || corr.
Destruction Pressure625 bar
Diameter22.8 mm
Drift Of The Sensitivity+/- 0.015 % of measurin.
Drift Of The Zero Point+/- 0.015 % of measurin.
Electrical Circuit Typecontrol circuit
Electrical Connection1 male connector M12, 3.
Eu Rohs DirectivePro-active compliance (.
Fluid Connection TypeG 1/4A (male) DIN 3852-E
Height58.1 mm
Ip Degree Of ProtectionIP66 conforming to EN/I.
Length48.5 mm
Local Displaywithout
Materials In Contact Wi.FPM (Viton) || stainles.
Maximum Permissible Acc.560 bar
Measurement Accuracy+/- 0.3 % of the measur.
Mechanical Durability10000000 cycles
Mercury FreeYes
Nema Degree Of Protecti.NEMA 4
Net Weight0.095 kg
Operating Positionany position
Pressure Sensor NameXMLG
Pressure Sensor Size250 bar
Pressure Sensor Typepressure transmitter
Pressure Setting Range0-250 bar
Product CertificationsEAC || CSA C22.2 No 14 .
Product Or Component Ty.electronic pressure sen.
Protection Typereverse polarity || loa.
Protective TreatmentTC
Quantity Per Setset of 1
Range Of ProductOsiSense XM
Reach RegulationReference contains Subs.
Repeat Accuracy+/- 0.1 % of the measur.
Resistance To Conducted.30 V 0.15-80 Hz)EN/IEC .
Resistance To Electroma.200 V/m 80-1000 Hz EN/I.
Resistance To Electrost.15 kV in air EN/IEC 610.
Resistance To Fast Tran.4 kV EN/IEC 61000-4-4
Resistance To Magnetic .30 A/m 50 Hz EN/IEC 610.
Rohs Exemption Informat.Yes
Scale Typefixed differential
Shock Resistance25 gn 11 ms EN/IEC 6006.
StandardsEN/IEC 61326-2-3 || CE
Surge Withstand1 kV 42 Ohm EN/IEC 6100.
Type Of Output Signalanalogue
Type Of Packingindividual
Vibration Resistance20 gn 9-2000 Hz)EN/IEC .
Warranty18 months