Attributes

Key Value
[Sa] Assured Operating .0.051-0.508 m teach mod.
[Sd] Sensing Range0.051-0.508 m
[Sn] Nominal Sensing Di.0.5-0.5 m adjustable wi.
[Us] Rated Supply Volta.12...24 V DC reverse po.
Ambient Air Temperature.-20-65 ?C
Ambient Air Temperature.-40-80 ?C
Beam Angle6 ?
Blind Zone0-51 mm
California Proposition .Diisononyl phthalate (D.
Current Consumption40 mA
Depth79 mm
Detection Systemdiffuse
Deviation Angle From 90.-7-7 ?
Discrete Output Function1 NO
Discrete Output TypePNP
Electrical Connectionmale connector M12 4 pi.
Enclosure Materialvalox
Eu Rohs DirectiveNot applicable, out of .
Front Materialepoxy
Height18 mm
Ip Degree Of ProtectionIP67 conforming to IEC .
MarkingCE
Materialplastic
Maximum Delay First Up100 ms
Maximum Delay Recovery10 ms
Maximum Delay Response10 ms
Maximum Differential Tr.2.5 mm
Maximum Switching Curre.100 mA overload and sho.
Maximum Voltage Drop1 V
Minimum Size Of Detecte.cylinder diameter 2.5 m.
Net Weight0.033 kg
Product CertificationsUL || cCSAus
Range Of ProductTelemecanique Ultrasoni.
Reach RegulationReference contains Subs.
Repeat Accuracy1.27 %
Resistance To Electroma.10 V/m level 3 IEC 6100.
Resistance To Electrost.8 kV level 4 IEC 61000-.
Resistance To Fast Tran.1 kV level 3 IEC 61000-.
Sensor Designcylindrical M18
Sensor NameXX5
Sensor Typeultrasonic sensor
Series Namegeneral purpose
Shock Resistance30 gn in all 3 axes 11 .
StandardsIEC 60947-5-2
Status Ledsupply on 1 LED green) .
Supply Voltage Limits10-28 V DC
Thread TypeM18 x 1
Threaded Length43 mm
Transmission Frequency300 kHz
Type Of Output Signaldiscrete
Vibration Resistance+/-1 mm 10-55 Hz)IEC 60.
Warranty18 months
Width18 mm
Wiring Technique3-wire
prev