Key Value
[Sd] Sensing Range0.0508-1 m
[Sn] Nominal Sensing Di.1-1 m
[Us] Rated Supply Volta.12...24 V DC overload a.
Ambient Air Temperature.0-50 ?C
Ambient Air Temperature.-20-80 ?C
Beam Angle10 ?
Blind Zone51-51 mm
California Proposition .Diisononyl phthalate (D.
Current Consumption100 mA
Depth30 mm
Device Short NameSM902
Discrete Output Function1 NC
Discrete Output TypeNPN
Electrical Connectioncable, 3 m
Enclosure MaterialULTEM
Eu Rohs DirectiveNot applicable, out of .
Front Materialsilicone rubber
Height30 mm
Ip Degree Of ProtectionIP67
Iso ThreadM30 x 1.5
Length95 mm
MarkingCE
Materialplastic
Maximum Differential Tr.2.5 mm
Maximum Switching Curre.100 mA reverse polarity.
Minimum Size Of Detecte.cylinder diameter 1.6 m.
Nema Degree Of Protecti.NEMA 4X indoor use only)
Net Weight0.6 kg
Product CertificationsUL
Product Specific Applic.dual-level - alarm
Range Of ProductHyde Park
Reach RegulationReference contains Subs.
Relative Humidity100-100 % without conde.
Repeat Accuracy0.87 %
Resistance To Electroma.10 V/m level 3 IEC 6100.
Resistance To Fast Tran.1 kV level 3 IEC 61000-.
Sensor Designcylindrical M30
Sensor Typeultrasonic sensor
Series NameSuperprox 900
Shock Resistance30 gn in all 3 axes 11 .
Supply Voltage Limits10-28 V DC
Transmission Frequency200 kHz
Type Of Output Signaldiscrete
Type Of Sensing Windowadjustable
Vibration Resistance+/-1 mm 10-55 Hz)IEC 60.
Warranty18 months
Width34.7 mm
Wiring Technique4-wire