Attributes

Key Value
[Ui] Rated Insulation V.300 V 2)DIN VDE 0110 pa.
[Uimp] Rated Impulse Wi.4 kV III DIN VDE 0110 p.
[Us] Rated Supply Volta.24 V DC - 20...20 %
Ambient Air Temperature.-10-55 ?C
Ambient Air Temperature.-25-85 ?C
Associated Fuse Rating4 A gG relay output DIN.
Breaking Capacity180 VA holding AC-15 C3.
California Proposition .Lead and lead compounds.
China Rohs RegulationX
Circularity ProfileENVEOLI1406024EN
Connections - Terminalscaptive screw clamp ter.
Environmental DisclosureENVPEP1406024EN
Eu Rohs DirectivePro-active compliance (.
Function Of Modulebuilt-in muting
Input CompatibilityXC limit switch muting .
Input Current200 mA muting function
Input Voltage24 V DCsensor || 24 V D.
Ip Degree Of ProtectionIP20 IEC 60529 terminal.
Local Signalling1 LED electronic intern.
Maximum Line Resistance10 Ohm sensor power sup.
Maximum Response Time O.25 ms
Maximum Supply Current .200 mA
Mercury FreeYes
Minimum Output Current10 mA relay output
Minimum Output Voltage17 V relay output
Muting Maximum Duration60 s - 10...30 %)
Number Of Additional Ci.0
Number Of Inputs2 MA, MB)muting functio.
Output Thermal Current5.6 A per relay || 11 A.
Output Typerelay 2 NO 13-14, 23-24.
Power Consumption In W15 W
Product Or Component Ty.safety module
Protection Typeelectronic internal fuse
Pvc FreeYes
Range Of ProductTelemecanique Safety li.
Reach RegulationReference contains Subs.
Rohs Exemption Informat.Yes
Safety Levelcan reach category 2 wi.
Safety Module Applicati.for monitoring of singl.
Safety Module NameXPSCM
Safety Reliability DataMTTFd = 16.6 years EN/I.
Sensor Power SupplyU+, U- 24-24 V DC
Sustainable Offer StatusGreen Premium product
Synchronisation Time Be.3 s +/- 20 %) for the a.
Warranty18 months
WeeeThe product must be dis.
prev