mpn
SQDXB5AK123G5C0
brand
name: SQUARE D
manufacturer
name: SQUARE D
Attributes
Key
Value
[Ie] Rated Operational .
3 A 240 V, AC-15, A600 .
[Ith] Conventional Free.
10 A EN/IEC 60947-5-1
[Ui] Rated Insulation V.
600 V 3)EN 60947-1
[Uimp] Rated Impulse Wi.
6 kV EN 60947-1
[Us] Rated Supply Volta.
110...120 V AC 50/60 Hz
Ambient Air Temperature.
-40-70 ?C
Ambient Air Temperature.
-40-70 ?C
Bezel Material
plastic colour plated g.
Bulb Base
integral LED
California Proposition .
Lead and lead compounds.
China Rohs Regulation
X
Contact Operation
slow-break
Contacts Material
silver alloy (Ag/Ni)
Contacts Type And Compo.
1 NO + 1 NC
Contacts Usage
standard contacts
Current Consumption
14 mA
Depth
70 mm
Device Presentation
complete product
Device Short Name
XB5
Electrical Durability
1000000 cycles, AC-15, .
Electrical Shock Protec.
class II IEC 60536
Electromagnetic Emission
class B IEC 55011
Eu Rohs Directive
Pro-active compliance (.
Head Type
standard
Height
42 mm
Ik Degree Of Protection
IK06 IEC 50102
Ip Degree Of Protection
IP66 IEC 60529 || IP67 .
Light Source
universal LED
Mechanical Durability
1000000 cycles
Mercury Free
Yes
Mounting Diameter
22 mm
Nema Degree Of Protecti.
NEMA 13 || NEMA 4X
Net Weight
0.516 kg
Operating Torque
0.14 N.m NO changing el.
Operator Position Infor.
2 positions 90?
Operator Profile
green standard handle
Positive Opening
with EN/IEC 60947-5-1 a.
Product Certifications
BV || CSA || UL || LROS.
Product Or Component Ty.
illuminated selector sw.
Protective Treatment
TH
Range Of Product
Harmony XB5
Reach Free Of Svhc
Yes
Reach Regulation
Free of Substances of V.
Resistance To Electroma.
10 V/m IEC 61000-4-3
Resistance To Electrost.
6 kV on contact (on met.
Resistance To Fast Tran.
2 kV IEC 61000-4-4
Resistance To High Pres.
7000000 Pa 55 ?C 0.1 m
Rohs Exemption Informat.
Yes
Sale Per Indivisible Qu.
1
Service Life
100000 h at rated volta.
Shape Of Screw Head
cross Philips no 1 || c.
Shape Of Signaling Unit.
round
Shock Resistance
30 gn 18 ms) half sine .
Short-Circuit Protection
10 A cartridge fuse gG .
Signalling Type
steady
Standards
EN/IEC 60947-5-1 || CSA.
Supply Voltage Limits
100-132 V AC
Surge Withstand
1 kV IEC 61000-4-5
Terminals Description I.
(11-12)NC || (13-14)NO
Tightening Torque
0.8-1.2 N.m EN 60947-1
Type Of Operator
stay put
Vibration Resistance
5 gn 2-500 Hz)IEC 60068.
Weee
The product must be dis.
Width
30 mm