mpn
02-201285
brand
name: Vickers
manufacturer
name: Vickers
Attributes
Key
Value
Adjustment type
Fixed Orifice
Application
Harvesters, refuse haul.
Cavity
C-16-2
Eccn
EAR99
Factory set flow rate
6 litre per minute
Flow rate12
114 litre per minute
Fluid compatibility13
MIL?H?5606, SAE 10, SAE.
Function
Flow Regulator
Housing
No
Icc2
SICV Flow Control Valves
Installation type
Screw-in Cartridge
Leakage
Standard
Maximum flow rate
114 litre per minute
Minimum flow rate
1.9 litre per minute
Model Code
FR1-16V-F-0-/6.00
Number of housing ports
2
Number of valve ports
2
Operating temperature
-40?C to +120?C
Port type
Cartridge Only
Pressure rating
210 bar
Product height
1.50
Product height uom
inch
Product length
2.87
Product length uom
inch
Product trade name
FR1-16 Series
Product weight
0.72
Product weight uom
pound
Product width
1.50
Product width uom
inch
Recommended filtration .
18/16/13 microns
Seal Type
Viton
Style
Pressure Compensated wi.
Sub brand
Vickers
Valve torque into cavity
108-122 Nm