As an Amazon Associate, we earn from qualifying purchases.

Order CEL-633.A2/K1 by Casella Broadband Environmental Sound level Meter - US Mega Store

Gallery

Attributes

Brand name, Manufacturer name, ManufacturerCasella
Attribute00, Attribute21IEC61672: 2002 Class 2, ANSI S1.4: Type 2 (1983)
Attribute01, Attribute22IEC61260: Class 0, ANSI S1.43: (1996)
Attribute02, Attribute23IEC61672 replaces 2 obsolete standards, IEC60651 andIEC60804
Attribute03, Attribute2420-140dB RMS (143.3dB peak)
Attribute04, Attribute2525dB(A) Class 2
Attribute05, Attribute26Fast, Slow and Impulse simultaneously
Attribute06, Attribute27A, C and Z (un-weighted) simultaneously
Attribute07, Attribute283, 4 and 5 simultaneously
Attribute08, Attribute29Last 10s in cumulative mode
Attribute09, Attribute30Duration 1s-24h
Attribute10, Attribute316 sets with selectable times and a repeat function
Attribute11, Attribute321/4" Whitworth socket
Attribute12, Attribute333x AA Alkaline, 10-15 hours dependent on back light
Attribute13, Attribute349-14V DC at 150mA
Attribute14, Attribute35332g including batteries
Attribute15, Attribute36230x72x31mm inc preamp and microphone
Attribute16, Attribute37LXY, LXYmax, LXYmin, LXeq, LXpeak, Lavg, LC-LA, LXIeq, LTM3, LTM5, LAE.Workplace dose values are calculated within insightsoftwareCEL-633 model additionally stores 5x Ln values. For time history data, all parameters are logged for period times plus 6 selectable profile parameters (plus 5x Ln values on CEL-633).
Attribute17, Attribute38Memory: 2GB (>1 year logging when set to 1 second interval, 999 runs). All parameters stored and accessible via Casella insight. Total measurement runs: 999.Events: 999 events/run. 10 hours of audio recording in high quality mode, 60 hours in low quality mode. For long term unattended monitoring the CEL-630 takes a new run daily for up to a total of 400 days.
Attribute18, Attribute39Low Quality: 8,000 samples/s at 8bit (64kb/s), up to 4kHz High Quality: 24,000 samples/s at 8 bit (192kb/s), up to 12kHz
Attribute19, Attribute40Operating 0 to 90%RH in the absence of condensation Conditions: Temperature of -10 to +50°C (Class 1) and 0 to 40°C (Class 2) Atmospheric pressure of 65 to 108kPa.
Attribute20, Attribute41User interface can be changed via the menu: English, French, German, Spanish, Italian, Portuguese, Chinese.
AttributeKey00, AttributeKey21Standards
AttributeKey01, AttributeKey22Filters
AttributeKey02, AttributeKey23Note
AttributeKey03, AttributeKey24Measurement range
AttributeKey04, AttributeKey25Total Noise floor
AttributeKey05, AttributeKey26Time weightings
AttributeKey06, AttributeKey27Frequency weightings
AttributeKey07, AttributeKey28Amplitude weighting (Q)
AttributeKey08, AttributeKey29Back erase
AttributeKey09, AttributeKey30Timers
AttributeKey10, AttributeKey31On/Off timer
AttributeKey11, AttributeKey32Tripod mount
AttributeKey12, AttributeKey33Batteries
AttributeKey13, AttributeKey34External power
AttributeKey14, AttributeKey35, Weight_AttribWeight
AttributeKey15, AttributeKey36Size
AttributeKey16, AttributeKey37Broadband
AttributeKey17, AttributeKey38Memory
AttributeKey18, AttributeKey39Audio Recording
AttributeKey19, AttributeKey40Environmental
AttributeKey20, AttributeKey41Languages
CategoryL1Test Equipment
CategoryL2Meters
CategoryL3Sound Level Meters
CategoryL4Casella CEL-633.A2/K1
ConditionNEW
Extra Product NameOrder CEL-633.A2/K1 by Casella Broadband Environmental Sound level Meter - US Mega Store
Weight332
WeightUnitg
moq, multiple, tierMinQty11
MPN, SKUCEL-633.A2/K1
namedSizeXXLARGE
qtyInStock-2
qtySourceFieldMap
snippet<p><strong>CEL-633.A2/K1 Includes Only: </strong> </p> <ul><li>CEL-633.A2 Type 2 environmental sound level meter<ul><li>Case </li> <li>Windscreen </li> <li>Calibration certificates </li> </ul> </li> <li>CEL-120/2 acoustic calibrator </li> <li>USB download cable </li> <li>Batteries </li> <li>ISC099 Insight software </li> </ul> <p><strong>Features with all optional accessories </strong> : </p> <ul><li>Ideal for environmental or occupational monitoring </li> <li>Easy to use switch-on-and-go functionality </li> <li>Latest digital technology with a high resolution color TFT display </li> <li>Pre-configured set-ups for occupational and environmental measurements </li> <li>Voice notes to annotate measurements </li> <li>Audio (WAV) recording </li> <li>Single measurement range up to 140dB, no range adjustment required </li> <li>Data markers, back erase function and audio recording </li> <li>Level triggered events for transient measurements </li> <li>Simultaneous measurement of all parameters with all frequency and time weightings </li> <li>2GB memory for more than 1 year of data storage </li> <li>Removable pre-amp </li> <li>Environmental outdoor kit available (sold sepatatly) </li> </ul> <p><strong>Applications </strong> </p> <ul><li><strong>Occupational Noise Measurement </strong> <ul><li>Workplace noise assessments according to ISO9612, OSHA 29CFR 1910.95 </li> <li>Selection of hearing protection </li> <li>Calculation of noise exposure </li> <li>Ensuring compliance with workplace noise legislation </li> </ul> </li> <li><strong>Environmental Noise Measurement </strong> <ul><li>Boundary noise assessments </li> <li>Noise nuisance complaints </li> <li>Measurements according to ISO1996, BS4142 </li> <li>UK Construction Section 61 notices </li> </ul> </li> </ul> <p>With advanced functionality and simple user interface, the 63x range is designed to make occupational and environmental noise measurements quickly and easily. </p> <p><strong>Occupational Noise Measurements </strong> </p> <p>The 63x series is designed to make workplace noise measurements as quick and simple as possible. The displayed information can be made as simple or comprehensive as required and all measurement parameters are stored simultaneously, so no incorrect measurements can be made. When the unit is calibrated with the CEL-120 calibrator, the calibration dates and times are stored and downloaded to Casella insight software, validating the accuracy of measurements. </p> <ul><li>Simultaneous measurements of all workplace noise parameters </li> <li>Standard set-ups for workplace noise legislation </li> <li>Measures parameters for hearing protection selection by the SNR, HML </li> <li>Analyse time history of noise levels </li> <li>Optional high range microphone, up to 165dB </li> </ul> <p><strong>Environmental Noise Measurements </strong> </p> <p>Data can be marked to signify any significant events, the data from which can be removed afterwards in insight software. Up to 60 hours of audio files can be stored, commonly used for noise source identification. Stored audio can be played back on the instrument using headphones (sold sepatatly) or downloaded to Casella insight software. For unattended monitoring, event mode (CEL-633) allows trigger levels (dB) to be set, so additional data (e.g. Leq, Lmax) is stored together with the audio file for later play back or analysis, as well as a profile down to 10ms intervals. An environmental noise monitoring kit is available (sold sepatatly) which protects the instrument and microphone from the weather and allows unattended monitoring for up 10 days. </p> <ul><li>Simultaneous broadband and frequency measurement </li> <li>Data markers </li> <li>Back erase function </li> <li>Real-time frequency analysis </li> <li>Single measurement range </li> <li>Triggered 'event' capture </li> </ul> <p><strong>Insight Management Software </strong> </p> <p>Casella Insight data management software is a powerful yet simple tool to download, analyse and report from either workplace or environmental noise data. </p> <ul><li>Analysis of noise level time history </li> <li>Replay voice notes and event audio </li> <li>Intuitive user interface </li> <li>Remove anomalous data from results </li> <li>Analysis of time history </li> <li>Generate comprehensive reports </li> <li>Store data by, person, place, location </li> <li>Manage multiple instruments and calibration </li> </ul>
tierPrice14158

Distributor offers

SellerSKUMOQIn stockMultiplePrices
usmegastore.comCEL-633.A2/K11-211 @ $4158.00
MegadepotCEL-633.A2/K1111 @ $3960.00