As an Amazon Associate, we earn from qualifying purchases.

Laurel Electronics Laureate 1/8 Din Digital Panel Meter, Basic Dpm With Green Leds, Universal 85-264 Vac Power, Two 8A Form C Contact Relays, 4-20 Ma, 0-10V, -10 To +10V Analog Output, No Communication Option, Load Cell Input, 6-Wire Ratio, Custom Rohs Compliant: Yes - L10110WM1

Attributes

Brand name, Manufacturer name, BrandLAUREL ELECTRONICS
ManufacturerLAUREL ELECTRONICS Laurel Electronics, Inc.
CategoryL1Automation & Process Control
CategoryL2More Automation & Process Control
Extra Product NameLaurel Electronics Laureate 1/8 Din Digital Panel Meter, Basic Dpm With Green Leds, Universal 85-264 Vac Power, Two 8A Form C Contact Relays, 4-20 Ma, 0-10V, -10 To +10V Analog Output, No Communication Option, Load Cell Input, 6-Wire Ratio, Custom Rohs Compliant: Yes - L10110WM1
jsonUrlDataAutomation & Process Control > More Automation & Process Control
moq, multiple, qtyInStock, tierMinQty1, Case, NumberOfItems, Number_of_items1
MPN, Part Number, Keyword, PartNumber, Part_numberL10110WM1
SKU01P4498
tierPrice1557
urlhttps://www.newark.com/01P4498?CMP=AFC-DATAALCHEMY
Product GroupBISS
ASIN, AsinB00RM7R5KW
AdultProduct, Autographed, Memorabilia, TradeInEligibleFalse
Bullet_pointAccuracy of 0.01% of full scale +/-2 counts at up to 60 conversions per second and 4 or 6-wire connection. Includes five green 14.2 mm (0.56 inch) LED digits, universal 85-264 Vac or 95-300 Vdc power, two 8A Form C contact relays, a 4-20 mA, 0-10V or -10 to +10V analog output. Power, inputs and outputs are mutually isolated. Sensitivity to +/-20 mV full scale with 1 microvolt resolution for use with load cells and microvolt sources, range set to Custom Scaling Zero adjust from -99,999 to +99,999, span adjust from 0 to +/-99,999 for readout in engineering units.
CatIndustrial & Scientific
CatId16310091
CatTree16310091 16310161 306506011 306528011 306529011
ClassificationId306532011
DisplayNameProcess Controllers
FeatureSensitivity to \xb120 mV full scale with 1 microvolt resolution for use with load cells and microvolt sources, range set to Custom Scaling
FetchTime1625433186 1625433193 1628927756 1628927762 1651430883 1677709041 1689859442 1714722950
Height152 2.0 2.00 41
IsBrandQueryTrue
ItemClassificationBASE_PRODUCT
ItemName, Item_name, TitleLaurel Electronics L10110WM1 Load Cell and Microvolt Meter, Custom Scaling, Green LED Digits, 85-264 Vac Power, Isolated Analog Output
Item_type_keywordprocess-controllers
Label, Man, Publisher, StudioLaurel Electronics, Inc.
Length6.5 6.50
Linkhttps://m.media-amazon.com/images/I/31vyPqLfshL._SL75_.jpg https://m.media-amazon.com/images/I/31vyPqLfshL.jpg
Marketplace_idATVPDKIKX0DER
Materiallead, iron
Model, ModelNumber, Model_numberLaureate Load Cell and Microvolt Meter
Power_source_typeBattery Powered
ProductCategoryId306532011 biss_display_on_website
ProductGroupBISS BISS Basic
ProductTypeELECTRIC_CIRCUIT_TESTING_DEVICE
ProductTypeNameELECTRIC_CIRCUIT_TESTING_DEVICE ELECTRONIC_COMPONENT PRECISION_MEASURING
Product_descriptionModel L10110WM1 by Laurel Electronics is a load cell and DC microvolt meter which includes a load cell and microvolt signal conditioner, 4 or 6-wire ratio, with customer specified scaling, universal 85-264 Vac or 95-300 Vdc power, two 8A Form C contact relays, a 4-20 mA, 0-10V or -10 to +10V analog output, and five green 14.2 mm (0.56 inch) LED digits. DC microvolt meter operation provides sensitivity down to +/-20 mV full scale with 1 µV resolution. A moving average digital filter assures quiet readings in electrically noisy environments. Zero and span may be scaled from 0 to +/-99,999. Meter accuracy is 0.01% of full scale +/- 2 counts. Custom curve linearization, available with the optional Extended main board, can extend the working range of load cells. An isolated 5, 10 or 24 Vdc isolated excitation output is standard and can power up to four 350-ohm load cells in parallel at 10V. The meter operates in a ratiometric mode to eliminate errors due to excitation variations. When excitation sense inputs are used in 6-wire connection, the meter compensates for variation in resistance of the transducer leads, thereby allowing long cable runs. High read rates at up to 60 or 50 conversions per second are ideal for peak or valley capture, real-time computer interface, and control. Peak and valley values are automatically captured. Modular architecture provides a choice of power supply boards, relay boards for alarm or control, analog output boards, and communication boards. Available communication boards include RS232, RS485, USB and Ethernet. The Modbus protocol is fully supported as is the simpler Custom ASCII protocol. Power and all inputs and outputs are mutually isolated. The meter fits in a 1/8 DIN panel cutout (92 x 45 mm) and is protected to NEMA 4X (IP65) when panel mounted. It is certified to CE, RoHS, and ETL / UL standards.
Product_site_launch_date2014-12-30T23:43:51.772Z
Rank1207768 1278439 1294492 1322505 715 731 735 758
SkuL10110WM1 LAUREL ELECTRONICS L10110WM1
Specification_metCE IP RoHS UL
URLhttps://m.media-amazon.com/images/I/31afxY5NJYL._SL75_.jpg https://m.media-amazon.com/images/I/31vyPqLfshL._SL75_.jpg
Unitinches
Unitsinches pixels pounds
VariantMAIN
WebsiteDisplayGroupbiss_basic_display_on_website
WebsiteDisplayGroupNameBISS Basic
Weight0.000625
Width275 5.0 5.00 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
Newark01P44981111 @ $557.00
RadwellL10110WM111

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Laurel Electronics L10110WM1 Load Cell and Microvolt Meter, Custom Scaling, Green LED Digits, 85-264 Vac Power, Isolated Analog Output
Brand: LAUREL ELECTRONICS
Model L10110WM1 by Laurel Electronics is a load cell and DC microvolt meter which includes a load cell and microvolt signal conditioner, 4 or 6-wire ratio, with customer specified scaling, universal 85-264 Vac or 95-300 Vdc power, two 8A Form C contact relays, a 4-20 mA, 0-10V or -10 to +10V analog output, and five green 14.2 mm (0.56 inch) LED digits. DC microvolt meter operation provides sensitivity down to +/-20 mV full scale with 1 µV resolution. A moving average digital filter assures quiet readings in electrically noisy environments. Zero and span may be scaled from 0 to +/-99,999. Meter accuracy is 0.01% of full scale +/- 2 counts. Custom curve linearization, available with the optional Extended main board, can extend the working range of load cells. An isolated 5, 10 or 24 Vdc isolated excitation output is standard and can power up to four 350-ohm load cells in parallel at 10V. The meter operates in a ratiometric mode to eliminate errors due to excitation variations. When excitation sense inputs are used in 6-wire connection, the meter compensates for variation in resistance of the transducer leads, thereby allowing long cable runs. High read rates at up to 60 or 50 conversions per second are ideal for peak or valley capture, real-time computer interface, and control. Peak and valley values are automatically captured. Modular architecture provides a choice of power supply boards, relay boards for alarm or control, analog output boards, and communication boards. Available communication boards include RS232, RS485, USB and Ethernet. The Modbus protocol is fully supported as is the simpler Custom ASCII protocol. Power and all inputs and outputs are mutually isolated. The meter fits in a 1/8 DIN panel cutout (92 x 45 mm) and is protected to NEMA 4X (IP65) when panel mounted. It is certified to CE, RoHS, and ETL / UL standards.
Details
  • Sensitivity to +/-20 mV full scale with 1 microvolt resolution for use with load cells and microvolt sources, range set to Custom Scaling
  • Zero adjust from -99,999 to +99,999, span adjust from 0 to +/-99,999 for readout in engineering units.
  • Accuracy of 0.01% of full scale +/-2 counts at up to 60 conversions per second and 4 or 6-wire connection.
  • Includes five green 14.2 mm (0.56 inch) LED digits, universal 85-264 Vac or 95-300 Vdc power, two 8A Form C contact relays, a 4-20 mA, 0-10V or -10 to +10V analog output.
  • Power, inputs and outputs are mutually isolated.
Listing
Product groupBISS Basic
Product typeELECTRIC_CIRCUIT_TESTING_DEVICE
ModelLaureate Load Cell and Microvolt Meter
Part numberL10110WM1
Items per pack1
LabelLaurel Electronics, Inc.
ManufacturerLaurel Electronics, Inc.
Catalog
FeatureSensitivity to \xb120 mV full scale with 1 microvolt resolution for use with load cells and microvolt sources, range set to Custom Scaling
CategoryIndustrial & Scientific
MPNL10110WM1
Product groupBISS
Product typeELECTRONIC_COMPONENT
ManufacturerLaurel Electronics, Inc.
View on Amazon (paid link)