As an Amazon Associate, we earn from qualifying purchases.

LMI B911-392SI

Gallery

Attributes

Brand name, Manufacturer name, BrandLMI
ManufacturerLMI Liquid Metronics Inc.
Extra Product NameLMI B911-392SI
moq, multiple, tierMinQty1, Number_of_items1
MPN, SKU, PartNumber, Part_numberB911-392SI
qtyInStock0
snippetB Series InformationGeneral DescriptionLMI Series B chemical metering pumps shall be positive displacement, Liquifram type pumps that are UL and CUL approved. Output volume shall be adjustable while pumps are in operation from zero to maximum ca
tierPrice12191.00
AdultProduct, Autographed, Batteries_included, Batteries_required, Memorabilia, TradeInEligibleFalse
AsinB07M7L9YQ8
Bullet_point4 function valve, 4-20 mA control
ClassificationId7656069011
DisplayNameDosing Pumps
FetchTime1704436445
Height, Width210 75
ItemClassificationBASE_PRODUCT
ItemName, Item_nameLMI Metering Pump B911-392SI 1.6 GPH, 150 psi, PVDF, Manual/External Control
Item_type_keywordscience-lab-dosing-pumps
Item_weight, Weight18.0
Linkhttps://m.media-amazon.com/images/I/311L9uou9qL._SL75_.jpg https://m.media-amazon.com/images/I/311L9uou9qL.jpg
Marketplace_idATVPDKIKX0DER
ProductTypeLAB_SUPPLY
Product_descriptionLMI Series B Metering Pump. (with 4FV) 1.6 GPH @ 150 PSI, Liquid End 392SI, 115 VAC 50/60 Hz, US Plug. 4-20 mA Input or pulse divide or multiply with Dual Manual Control Stroke frequency control via 4-20 mA signal input or pulse input (divide/multiply/batch), manual stroke length control. Stroke frequency is manually adjustable when in local control. Includes low level float switch input. General Description LMI Series B chemical metering pumps shall be positive displacement, Liquifram type pumps that are UL and CUL approved. Output volume shall be adjustable while pumps are in operation from zero to maximum capacity. Pump Controls Series B9 metering pumps shall have a clear liquid crystal display. Control shall be selectable between internal and external pulsing by means of a tactile keypad. Internal stroke frequency shall be adjustable from 1 stroke per hour to 100 strokes per minute. Pressure capacity shall be keypad adjustable to reduce noise, vibration and wear. Metering pump shall be capable of dividing or multiplying pulse inputs from 1 to 999 or responding directly or inversely to a 4-20mA input signal. Drive Assembly The pump drive shall be totally enclosed with no exposed moving parts. Electronics shall be housed in chemical resistant enclosure at the rear of the pump for maximum protection against chemical spillage. Electrical power consumption shall not exceed 29 watts per hour under full speed and maximum pressure conditions. Pump weight shall not exceed 15 lbs (6.9 kg). Check Valve, Tubing, Connections A total of 16 ft (4.8 m) of tubing shall be provided per pump complete with compressing connections (on models with tubing connections). A foot valve with integral one piece strainer shall be provided for the suction line (on non-high viscosity models with tubing connections), and an injection check/back pressure valve with 1/2" NPT male connection for the injection point (on models with tubing connections).
Product_site_launch_date2019-01-09T08:00:00.000Z
Unitpounds
VariantMAIN
WebsiteDisplayGroupbiss_basic_display_on_website
WebsiteDisplayGroupNameBISS Basic

Distributor offers

SellerSKUMOQIn stockMultiplePrices
burtprocess.comB911-392SI111 @ $2191.00
industrialzone.comB911-392SI1-211 @ $2191.00
novatech-usa.comLMI-B911-392SI1-21
primebuy.comB911-392SI1Contact Us11 @ $2191.00

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

LMI Metering Pump B911-392SI 1.6 GPH, 150 psi, PVDF, Manual/External Control
Brand: LMI
LMI Series B Metering Pump. (with 4FV) 1.6 GPH @ 150 PSI, Liquid End 392SI, 115 VAC 50/60 Hz, US Plug. 4-20 mA Input or pulse divide or multiply with Dual Manual Control Stroke frequency control via 4-20 mA signal input or pulse input (divide/multiply/batch), manual stroke length control. Stroke frequency is manually adjustable when in local control. Includes low level float switch input. General Description LMI Series B chemical metering pumps shall be positive displacement, Liquifram type pumps that are UL and CUL approved. Output volume shall be adjustable while pumps are in operation from zero to maximum capacity. Pump Controls Series B9 metering pumps shall have a clear liquid crystal display. Control shall be selectable between internal and external pulsing by means of a tactile keypad. Internal stroke frequency shall be adjustable from 1 stroke per hour to 100 strokes per minute. Pressure capacity shall be keypad adjustable to reduce noise, vibration and wear. Metering pump shall be capable of dividing or multiplying pulse inputs from 1 to 999 or responding directly or inversely to a 4-20mA input signal. Drive Assembly The pump drive shall be totally enclosed with no exposed moving parts. Electronics shall be housed in chemical resistant enclosure at the rear of the pump for maximum protection against chemical spillage. Electrical power consumption shall not exceed 29 watts per hour under full speed and maximum pressure conditions. Pump weight shall not exceed 15 lbs (6.9 kg). Check Valve, Tubing, Connections A total of 16 ft (4.8 m) of tubing shall be provided per pump complete with compressing connections (on models with tubing connections). A foot valve with integral one piece strainer shall be provided for the suction line (on non-high viscosity models with tubing connections), and an injection check/back pressure valve with 1/2" NPT male connection for the injection point (on models with tubing connections).
Details
  • 4 function valve, 4-20 mA control
View on Amazon (paid link)