As an Amazon Associate, we earn from qualifying purchases.

Order CDTR-5W404 by Dwyer CDTR Carbon Dioxide Transmitter - US Mega Store

Gallery

Attributes

Brand name, Manufacturer name, BrandDwyer
ManufacturerDwyer Dwyer Instruments, Inc.
Attribute00, Attribute13CO2: 0 to 5000; Relative Humidity: 0 to 100% ; Temperature: 32 to 122°F (0 to 50°C)
Attribute01, Attribute14±40 ppm + 3% of reading (CO2); ±2% (RH)
Attribute02, Attribute15±8 ppm/ °C at 1100 ppm
Attribute03, Attribute1616 ppm
Attribute04, Attribute170.13% of reading per mm of Hg
Attribute05, Attribute182 minutes for 99% step change
Attribute06, Attribute1932 to 122°F (0 to 50°C)
Attribute07, Attribute2010 to 95% RH (non-condensing)
Attribute08, Attribute2116 to 35 VDC / 19 to 28 VAC
Attribute09, Attribute22Average: 2 watts; Peak: 3.75 watts
Attribute10, Attribute23Single-beam, dual-wavelength NDIR
Attribute11, Attribute245.6 oz (158.8 g)
Attribute12, Attribute25CE
AttributeKey00, AttributeKey13Range
AttributeKey01, AttributeKey14Accuracy
AttributeKey02, AttributeKey15Temperature Dependence
AttributeKey03, AttributeKey16Non-Linearity
AttributeKey04, AttributeKey17Pressure Dependence
AttributeKey05, AttributeKey18Response Time
AttributeKey06, AttributeKey19Temperature Limits
AttributeKey07, AttributeKey20Humidity Limits
AttributeKey08, AttributeKey21Power Requirements
AttributeKey09, AttributeKey22Power Consumption
AttributeKey10, AttributeKey23Sensor
AttributeKey11, AttributeKey24, Weight_AttribWeight
AttributeKey12, AttributeKey25Agency Approvals
CategoryL1Process Control & Automation
CategoryL2Transmitters
CategoryL3Gas
CategoryL4Dwyer CDTR-5W404
ConditionNEW
Extra Product NameOrder CDTR-5W404 by Dwyer CDTR Carbon Dioxide Transmitter - US Mega Store
Weight5.6
WeightUnitoz
moq, multiple, tierMinQty1, Case, Item_package_quantity, NumberOfItems, PackageQuantity1
MPN, SKU, Part Number, Mpns, PartNumber, Part_numberCDTR-5W404
qtyInStockContact Us
snippet<p><strong>Dwyer, CDTR-5W404, Series CDTR Carbon Dioxide/RH/Temperature Transmitter, 5000 ppm, Wall Mount </strong> </p> <p>NDIR CO2 Sensor, Universal CO2/RH Outputs </p> <p><strong>Series CDTR Carbon Dioxide, Relative Humidity and Temperature Transmitters </strong> reduce the number of sensors mounted on a wall or in a duct. By combining CO2, RH, and temperature in one device, system integrators are able to lower installation time of mounting multiple housings, while lowering material cost at the same time. Even with the three sensors combined into a single unit, replacement cost is not increased due to the pluggable nature of the humidity sensor, which allows it or the temperature to be replaced at a fraction of the cost of a new CO2 transmitter. </p> <p>Like our popular Series CDT Carbon Dioxide Transmitter, a single-beam dualwavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light source aging effects. The single-beam dual-wavelength sensor technology provides a higher level of accuracy compared to Automatic Baseline Correction methods which can unintentionally shift the calibration based on CO2 levels and barometric pressure conditions. </p> <p>Universal outputs for both carbon dioxide and relative humidity allow users to select the transmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with virtually any building management controller. Additionally, passive thermistor or RTD sensor can be ordered for a temperature output. When ordering a duct mount configuration or a wall mount configuration without the display, the Model A- 449 or A-449A remote LCD display can plug into the miniature connector port on the transmitter. The display can be configured to display temperature only, relative humidity only, CO2 only, CO2 and humidity, or CO2 and temperature. Push buttons are standard on all configurations of the transmitters for access to the menu structure, but wall mount configurations can be ordered without the buttons. To prevent tampering, the action of the buttons can be locked out using an internal jumper selection. Menu items that can be accessed via the push buttons include: engineering units, relay output set points, display configuration, transmitter output scaling, ambient barometric pressure, and field calibration of the transmitter. </p> <p>*For buildings occupied 24 hours per day, it is recommended that calibration be verified every 6 to 12 months depending on application. </p> <p><strong>Approvals </strong> </p> <ul><li>CE Approval (Duct) </li> <li>RoHS </li> <li>CE Approval CDTR-E/N </li> </ul>
tierPrice1309.7
Product GroupBISS
ASIN, AsinB00D2NINWE
AdultProduct, Autographed, Memorabilia, TradeInEligibleFalse
Aspecttransportation_regulatory_class
Bullet_pointAPPLICATIONS: Demand control ventilation in schools, office buildings, hospitals, and other indoor environments; LEED certification. Digital Intelligence Temperature Compensation Algorithm (DITCA) eliminates error due to the self- heating effects of wall-mount combination devices Model CDTR-5W404Dwyer CO2/RH/Temp Transmitter, Wall Mount, 4-20mA/0-(5 or 10) VDC Output. No Display. Replaceable humidity/temperature sensors; Physical hardware lockout. Single beam dual wavelength NDIR CO2 sensor eliminates drift due to light source aging
CatTools & Home Improvement
CatId228013
CatTree228013 468240 495346 551240
ClassificationId13400031
DisplayNameHVAC Controls
FeatureBarometric Pressure Dependence: 0.13% of reading per mm of Hg.
FetchTime1645868314 1683783576 1704706340
Hazmat0
Height, Width1000 500 75
IsAutographed, IsMemorabiliafalse
ItemClassificationBASE_PRODUCT
ItemName, Item_name, TitleDwyer CO2/RH/Temp Transmitter, CDTR-5W404, Wall Mount, 4-20mA/0-(5 or 10) VDC Output
Item_type_keywordindoor-air-quality-meters
Keyword10-4
Label, Man, Publisher, StudioDwyer Instruments, Inc.
Linkhttps://m.media-amazon.com/images/I/31WEzOag+0L._SL75_.jpg https://m.media-amazon.com/images/I/31WEzOag+0L.jpg https://m.media-amazon.com/images/I/41ItvdrwS-L._SL75_.jpg https://m.media-amazon.com/images/I/41ItvdrwS-L.jpg https://m.media-amazon.com/images/I/51jpdcwf+pL.jpg
Marketplace_idATVPDKIKX0DER
ProductGroupBISS BISS Basic
ProductType, ProductTypeNameMECHANICAL_COMPONENTS
Product_descriptionThe SERIES CDTR Carbon Dioxide, Relative Humidity and Temperature Transmitters reduce the number of sensors mounted on a wall or in a duct. By combining CO2, RH, and temperature in one device, system integrators reduce installation time while lowering material cost. A single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light-source aging effects. Digital barometric pressure adjustment and field-calibratable sensor. Universal outputs for CO2 and RH enable users to select the transmitter output: 4 to 20 mA; 0 to 5 VDC or 0 to 10 VDC to work with virtually any building management controller. Display can be configured to report temp only, RH only, CO2 only, CO2 and RH, or CO2 and temp. Push buttons for access to the menu structure are standard. To prevent tampering, the action of the buttons can be locked out using an internal jumper selection. APPLICATIONS: Demand control ventilation in schools, office buildings, hospitals, and other indoor environments; LEED certification. SPECIFICATIONS: Range: CO2: 0 to 2000 or 0 to 5000 ppm (depending on model); Relative humidity: 0 to 100% ; Temperature: 32 to 122°F (0 to 50°C). Accuracy: ±40 ppm + 3% of reading (CO2); ±2% (RH). Temperature Dependence: ±8 ppm/ °C at 1100 ppm. Non-Linearity: 16 ppm. Pressure Dependence: 0.13% of rdg per mm of Hg. Response Time: 2 minutes for 99% step change. Temp Limits: 32 to 122°F (0 to 50°C). Humidity Limits: 10 to 95% RH (non-condensing). Power Rqts: 16 to 35 VDC / 19 to 28 VAC. Power Consumption: Average: 2 watts; Peak: 3.75 watts. Sensor: Single-beam, dual-wavelength NDIR. Output: Current: 4 to 20 mA (max 500 Ω); Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω); Relay: SPST NO 2A @ 30 VDC; RTD or thermistor per r-t curves (depending on model). Weight: 5.6 oz (158.8 g). Enclosure Rating: IP20. Agency Approvals: CE.
Product_site_launch_date2017-05-31T07:00:00.000Z
StrippedMpnsCDTR5W404
URLhttps://m.media-amazon.com/images/I/31WEzOag+0L._SL75_.jpg
Unitspixels
VariantMAIN PT01
WebsiteDisplayGroupbiss_basic_display_on_website
WebsiteDisplayGroupNameBISS Basic

Distributor offers

SellerSKUMOQIn stockMultiplePrices
usmegastore.comCDTR-5W4041Contact Us11 @ $309.70
heavydutydepot.comCDTR-5W404111 @ $309.70
MegadepotCDTR-5W40411
us.rs-online.com72076223111 @ $255.97, 3 @ $248.68
RadwellCDTR-5W40411
TranscatCDTR-5W40411
Allied Electronics7207622311

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Dwyer CO2/RH/Temp Transmitter, CDTR-5W404, Wall Mount, 4-20mA/0-(5 or 10) VDC Output
Brand: Dwyer
The SERIES CDTR Carbon Dioxide, Relative Humidity and Temperature Transmitters reduce the number of sensors mounted on a wall or in a duct. By combining CO2, RH, and temperature in one device, system integrators reduce installation time while lowering material cost. A single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light-source aging effects. Digital barometric pressure adjustment and field-calibratable sensor. Universal outputs for CO2 and RH enable users to select the transmitter output: 4 to 20 mA; 0 to 5 VDC or 0 to 10 VDC to work with virtually any building management controller. Display can be configured to report temp only, RH only, CO2 only, CO2 and RH, or CO2 and temp. Push buttons for access to the menu structure are standard. To prevent tampering, the action of the buttons can be locked out using an internal jumper selection. APPLICATIONS: Demand control ventilation in schools, office buildings, hospitals, and other indoor environments; LEED certification. SPECIFICATIONS: Range: CO2: 0 to 2000 or 0 to 5000 ppm (depending on model); Relative humidity: 0 to 100% ; Temperature: 32 to 122°F (0 to 50°C). Accuracy: ±40 ppm + 3% of reading (CO2); ±2% (RH). Temperature Dependence: ±8 ppm/ °C at 1100 ppm. Non-Linearity: 16 ppm. Pressure Dependence: 0.13% of rdg per mm of Hg. Response Time: 2 minutes for 99% step change. Temp Limits: 32 to 122°F (0 to 50°C). Humidity Limits: 10 to 95% RH (non-condensing). Power Rqts: 16 to 35 VDC / 19 to 28 VAC. Power Consumption: Average: 2 watts; Peak: 3.75 watts. Sensor: Single-beam, dual-wavelength NDIR. Output: Current: 4 to 20 mA (max 500 Ω); Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω); Relay: SPST NO 2A @ 30 VDC; RTD or thermistor per r-t curves (depending on model). Weight: 5.6 oz (158.8 g). Enclosure Rating: IP20. Agency Approvals: CE.
Details
  • Model CDTR-5W404Dwyer CO2/RH/Temp Transmitter, Wall Mount, 4-20mA/0-(5 or 10) VDC Output. No Display.
  • Digital Intelligence Temperature Compensation Algorithm (DITCA) eliminates error due to the self- heating effects of wall-mount combination devices
  • Single beam dual wavelength NDIR CO2 sensor eliminates drift due to light source aging
  • Replaceable humidity/temperature sensors; Physical hardware lockout.
  • APPLICATIONS: Demand control ventilation in schools, office buildings, hospitals, and other indoor environments; LEED certification.
Listing
Product groupBISS Basic
Product typeMECHANICAL_COMPONENTS
Part numberCDTR-5W404
LabelDwyer Instruments, Inc.
ManufacturerDwyer Instruments, Inc.
Catalog
FeatureBarometric Pressure Dependence: 0.13% of reading per mm of Hg.
CategoryTools & Home Improvement
MPNCDTR-5W404
Product groupBISS
Product typeMECHANICAL_COMPONENTS
ManufacturerDwyer Instruments, Inc.
View on Amazon (paid link)