Laurel Electronics Laureate 1/8 Din Digital Panel Meter, Basic Dpm With Green Leds, Low Voltage Power 12-30 Vac Or 10-48 Vdc, No Relays, 4-20 Ma, 0-10V, -10 To +10V Analog Output, Ethernet Communications (Lnet Board), Load Cell Input, 6-Wire Ratio, Rohs Compliant: Yes - L11017WM1
Attributes
Distributor offers
| Seller | SKU | MOQ | In stock | Multiple | Prices |
|---|---|---|---|---|---|
| Newark | 95Y3787 | 1 | 1 | 1 @ $788.00 | |
| Newark | 57W6869 | 1 | 1 |
Related on Amazon
As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Laurel Electronics L11017WM1 Load Cell and Microvolt Meter, Custom Scaling, Green LED Digits, 10-48 Vdc Power, Isolated Analog Output, Ethernet Data I/O
Brand: LAUREL ELECTRONICS
Model L11017WM1 by Laurel Electronics is a load cell and DC microvolt meter which includes a load cell and microvolt signal conditioner, 4 or 6-wire ratio, with customer specified scaling, 10-48 Vdc or 12-34 Vac power, a 4-20 mA, 0-10V or -10 to +10V analog output, and five green 14.2 mm (0.56 inch) LED digits. DC microvolt meter operation provides sensitivity down to +/-20 mV full scale with 1 µV resolution. A moving average digital filter assures quiet readings in electrically noisy environments. Zero and span may be scaled from 0 to +/-99,999. Meter accuracy is 0.01% of full scale +/- 2 counts. Custom curve linearization, available with the optional Extended main board, can extend the working range of load cells. An isolated 5, 10 or 24 Vdc isolated excitation output is standard and can power up to four 350-ohm load cells in parallel at 10V. The meter operates in a ratiometric mode to eliminate errors due to excitation variations. When excitation sense inputs are used in 6-wire connection, the meter compensates for variation in resistance of the transducer leads, thereby allowing long cable runs. High read rates at up to 60 or 50 conversions per second are ideal for peak or valley capture, real-time computer interface, and control. Peak and valley values are automatically captured. Modular architecture provides a choice of power supply boards, relay boards for alarm or control, analog output boards, and communication boards. Available communication boards include RS232, RS485, USB and Ethernet. The Modbus protocol is fully supported as is the simpler Custom ASCII protocol. Power and all inputs and outputs are mutually isolated. The meter fits in a 1/8 DIN panel cutout (92 x 45 mm) and is protected to NEMA 4X (IP65) when panel mounted. It is certified to CE, RoHS, and ETL / UL standards.
Details
- Sensitivity to +/-20 mV full scale with 1 microvolt resolution for use with load cells and microvolt sources, range set to Custom Scaling
- Zero adjust from -99,999 to +99,999, span adjust from 0 to +/-99,999 for readout in engineering units.
- Accuracy of 0.01% of full scale +/-2 counts at up to 60 conversions per second and 4 or 6-wire connection.
- Includes five green 14.2 mm (0.56 inch) LED digits, 10-48 Vdc or 12-34 Vac power, a 4-20 mA, 0-10V or -10 to +10V analog output, Ethernet data I/O.
- Power, inputs and outputs are mutually isolated.
Listing
| Product group | BISS Basic |
|---|---|
| Product type | PRECISION_MEASURING |
| Model | Laureate Load Cell and Microvolt Meter |
| Part number | L11017WM1 |
| Label | Laurel Electronics, Inc. |
| Manufacturer | Laurel Electronics, Inc. |
Catalog
| Feature | Sensitivity to \xb120 mV full scale with 1 microvolt resolution for use with load cells and microvolt sources, range set to Custom Scaling |
|---|---|
| Category | Industrial & Scientific |
| MPN | L11017WM1 |
| Product group | BISS |
| Product type | ELECTRONIC_COMPONENT |
| Manufacturer | Laurel Electronics, Inc. |