As an Amazon Associate, we earn from qualifying purchases.

Laurel . L20104P392C

Attributes

Brand name, Manufacturer nameLaurel
ManufacturerLaurel Laurel Electronics, Inc.
extendedQty, qtyInStock0
moq, multiple, Case, NumberOfItems1
MPN, Part Number, PartNumber, Part_numberL20104P392C
qtySourceupdateFromUrlEntry
Product GroupBISS
ASIN, AsinB00RURWYB4
AdultProduct, Autographed, Memorabilia, TradeInEligibleFalse
BrandLAUREL ELECTRONICS
Bullet_pointDisplay resolution of 1 deg, 0.1 deg or 0.01 deg, deg C or deg F. Factory calibrated for 100-ohm platinum (Pt100) RTD with alpha or 0.003902, 10-ohm copper RTD with alpha of 0.00427, and 120-ohm nickel RTD with alpha of 0.00672. Includes five red 14.2 mm (0.56 inch) LED digits, universal 85-264 Vac or 95-300 Vdc power, two 8A Form C contact relays, RS485 data I/O with dual RJ45 connectors. Optional 2 or 4 relays can turn meter into an On/Off temperature controller. Power, inputs and outputs are mutually isolated. 3 or 4-wire RTD connection eliminates effects of lead resistance.
CatIndustrial & Scientific
CatId16310091
CatTree16310091 16310161 306506011 306528011 306529011
ClassificationId306532011
DisplayNameProcess Controllers
FeatureFactory calibrated for 100-ohm platinum (Pt100) RTD with alpha or 0.003902, 10-ohm copper RTD with alpha of 0.00427, and 120-ohm nickel RTD with alpha of 0.00672.
FetchTime1566519290 1684227489 1704691509
Height140 2.00 38
ItemClassificationBASE_PRODUCT
ItemName, Item_nameLaurel Electronics L20104P392C RTD Temperature Meter, Pt100 100 Ohm Platinum RTD, ANSI Alpha, -202 to 850°C, Red LED Digits, 85-264 Vac Power, RS485 Data I/O
Item_type_keywordprocess-controllers
Label, Man, Publisher, StudioLaurel Electronics, Inc.
Length6.50
Linkhttps://m.media-amazon.com/images/I/316S075JMiL._SL75_.jpg https://m.media-amazon.com/images/I/316S075JMiL.jpg
Marketplace_idATVPDKIKX0DER
Model, ModelNumber, Model_numberLaureate Pt100 RTD Meter
ProductGroupBISS BISS Basic
ProductTypeTHERMOMETER
ProductTypeNameELECTRONIC_COMPONENT PRECISION_MEASURING
Product_descriptionModel L20104P392C by Laurel Electronics is a Resistance Temperature Detector (RTD) temperature meter which includes an RTD signal conditioner set for Pt100 100 ohm platinum RTD, ANSI alpha, -202 to 850°C, universal 85-264 Vac or 95-300 Vdc power, two 8A Form C contact relaysand a five red 14.2 mm (0.56 inch) LED digits. Four RTD types are user selectable: 100-ohm platinum (Pt100) with DIN alpha of 0.00385, 100-ohm platinum (Pt100) with ANSI alpha of 0.003902, 10-ohm copper with alpha of 0.00427, and 120-ohm nickel with alpha of 0.00672. The entire span of each RTD type is presented in a single range. All ranges for all RTD types are digitally calibrated at the factory, with calibration factors stored in an EEPROM on the signal conditioner board. This allows temperatures sensors and signal conditioner boards to be changed in the field without recalibrating the meter. The RTD type, unit of measure (deg C or F) and resolution (1, 0.1 or 0.01 deg) are selectable from the front panel or via the meter's optional serial interface. Typical accuracy is +/-0.1°C (+/-0.2°F) at up to 60 conversions per second. The RTD connections can be via 2, 3 or 4 wires. With 3 or 4-wire connections, the meter automatically compensates for changes in lead resistance to the sensor. Digital filtering is selectable for electrically noisy environments or resolution to 0.01°. Modular architecture provides a choice of power supply boards, relay boards for alarm or control, analog output boards, and communication boards. Available communication boards include RS232, RS485, USB and Ethernet. The Modbus protocol is fully supported as is the simpler Custom ASCII protocol. Power and all inputs and outputs are mutually isolated. The meter fits in a 1/8 DIN panel cutout (92 x 45 mm) and is protected to NEMA 4X (IP65) when panel mounted. It is certified to CE, RoHS, and ETL / UL standards.
Product_site_launch_date2015-01-06T02:08:31.550Z
Specification_metANSI CE IP RoHS UL
TitleLaurel Electronics L20104P392C RTD Temperature Meter, Pt100 100 Ohm Platinum RTD, ANSI Alpha, -202 to 850\xb0C, Red LED Digits, 85-264 Vac Power, Isolated Analog Output, RS485 Data I/O Laurel Electronics L20104P392C RTD Temperature Meter, Pt100 100 Ohm Platinum RTD, ANSI Alpha, -202 to 850°C, Red LED Digits, 85-264 Vac Power, RS485 Data I/O
URLhttp://ecx.images-amazon.com/images/I/316S075JMiL._SL75_.jpg https://m.media-amazon.com/images/I/316S075JMiL._SL75_.jpg
Unitsinches pixels
VariantMAIN
WebsiteDisplayGroupbiss_basic_display_on_website
WebsiteDisplayGroupNameBISS Basic
Width275 5.00 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
Newark58W071611

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Laurel Electronics L20104P392C RTD Temperature Meter, Pt100 100 Ohm Platinum RTD, ANSI Alpha, -202 to 850°C, Red LED Digits, 85-264 Vac Power, RS485 Data I/O
Brand: LAUREL ELECTRONICS
Model L20104P392C by Laurel Electronics is a Resistance Temperature Detector (RTD) temperature meter which includes an RTD signal conditioner set for Pt100 100 ohm platinum RTD, ANSI alpha, -202 to 850°C, universal 85-264 Vac or 95-300 Vdc power, two 8A Form C contact relaysand a five red 14.2 mm (0.56 inch) LED digits. Four RTD types are user selectable: 100-ohm platinum (Pt100) with DIN alpha of 0.00385, 100-ohm platinum (Pt100) with ANSI alpha of 0.003902, 10-ohm copper with alpha of 0.00427, and 120-ohm nickel with alpha of 0.00672. The entire span of each RTD type is presented in a single range. All ranges for all RTD types are digitally calibrated at the factory, with calibration factors stored in an EEPROM on the signal conditioner board. This allows temperatures sensors and signal conditioner boards to be changed in the field without recalibrating the meter. The RTD type, unit of measure (deg C or F) and resolution (1, 0.1 or 0.01 deg) are selectable from the front panel or via the meter's optional serial interface. Typical accuracy is +/-0.1°C (+/-0.2°F) at up to 60 conversions per second. The RTD connections can be via 2, 3 or 4 wires. With 3 or 4-wire connections, the meter automatically compensates for changes in lead resistance to the sensor. Digital filtering is selectable for electrically noisy environments or resolution to 0.01°. Modular architecture provides a choice of power supply boards, relay boards for alarm or control, analog output boards, and communication boards. Available communication boards include RS232, RS485, USB and Ethernet. The Modbus protocol is fully supported as is the simpler Custom ASCII protocol. Power and all inputs and outputs are mutually isolated. The meter fits in a 1/8 DIN panel cutout (92 x 45 mm) and is protected to NEMA 4X (IP65) when panel mounted. It is certified to CE, RoHS, and ETL / UL standards.
Details
  • Factory calibrated for 100-ohm platinum (Pt100) RTD with alpha or 0.003902, 10-ohm copper RTD with alpha of 0.00427, and 120-ohm nickel RTD with alpha of 0.00672.
  • Display resolution of 1 deg, 0.1 deg or 0.01 deg, deg C or deg F.
  • Optional 2 or 4 relays can turn meter into an On/Off temperature controller.
  • Includes five red 14.2 mm (0.56 inch) LED digits, universal 85-264 Vac or 95-300 Vdc power, two 8A Form C contact relays, RS485 data I/O with dual RJ45 connectors.
  • Power, inputs and outputs are mutually isolated. 3 or 4-wire RTD connection eliminates effects of lead resistance.
Listing
Product groupBISS Basic
Product typePRECISION_MEASURING
ModelLaureate Pt100 RTD Meter
Part numberL20104P392C
LabelLaurel Electronics, Inc.
ManufacturerLaurel Electronics, Inc.
Catalog
FeatureFactory calibrated for 100-ohm platinum (Pt100) RTD with alpha or 0.003902, 10-ohm copper RTD with alpha of 0.00427, and 120-ohm nickel RTD with alpha of 0.00672.
CategoryIndustrial & Scientific
MPNL20104P392C
Product groupBISS
Product typeELECTRONIC_COMPONENT
ManufacturerLaurel Electronics, Inc.
View on Amazon (paid link)