The NEW Purifier Logic Plus Class II A2 Biosafety Cabinet excels in user comfort and functionality. Decades of industry leading advances in ergonomic design have shaped the Inclination Technology Suite that includes the following: 10 Degree angled sash, patented curved air grille with built in armrest, fully accessible controls and eye-level mounted color display with MyLogic operating system. MyLogic provides intuitive programming, color coded menus, status messages and alarms with diagnostic troubleshooting ? all using full sentences. Using the same ECM blower technology as the Purifier Logic, the Logic Plus uses the Constant Airflow Profile (CAP) to maintain a precise volume of air as the filters load. In addition, the cabinet will continuously display the HEPA filter life remaining and cabinet status. These features combine to provide unparalleled safety. The cabinet provides personnel, product and environmental protection and is suitable for work in biosafety levels 1, 2 and 3. These biohazard cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. In addition, some models have base stands as well as other options included. Please refer to product specifications.
The newly redesigned, patented* Protector Stream Laboratory Hood was engineered to be the best containing fume hood possible. Testing shows the Protector Stream easily meets containment per SEFA-1 low velocity hood standards when subjected to the ASHRAE 110 test protocol with results of less than 0.05 ppm leak rate when tested at 4.0 lap at OSHA-recognized 60 fpm face velocity. Using the concepts of fluid dynamics, Laconic engineers designed the Protector Stream Laboratory Hood to produce horizontal airflow, which reduces the tendencies for turbulence. The innovative and aerodynamic designs of the sash handle, air foil, upper dilution air supply and rear down flow baffle work in concert to produce horizontal airflow patterns that significantly reduce concentrations of chemical contaminants throughout the work area, particularly near the operator's breathing zone and at the work surface. Depending on sash position, tendencies for air turbulence, overtaxing and "the roll" frequently observed during traditional fume hood smoke tests are virtually eliminated. Safety is foremost, but energy savings is equally impressive. Operating a 6' Protector Stream Hood at 60 fpm face velocity, with the sash in its fully open position, requires only 690 CFM. Regardless of your desired operating face velocity, the Protector Stream yields the lowest required CFM. Energy savings translates to dollar savings. The Protector Stream Hood provides an excellent economic payback when compared to traditional by-pass hoods operated at 80 or 100 fpm. For even greater savings, the Protector Stream may be factory-prepared to accommodate a variable air volume system without the need for by-pass modifications.