Ahlstrom manufactures a complete line of high quality chromatography, electrophoresis and blotting papers for use in gel transfer applications and chromatography techniques. These uniform, smooth, white sheets are the high purity, high quality, and high value standard. They are used in nucleic acid research such as Southern, Northern and Western blots, electroblotting and electrophoresis. Ahlstrom chromatography, electrophoresis and blotting papers are made from high purity and 100% FDA compliant alpha cotton cellulose, using ultra-pure RO water and contain no additives that could cause increased backgrounds or other interference in detection systems. Controlled absorption Uniform absorption Consistency across the sheet Lot-to-lot consistency High purity, no sizing or fillers E x cellent wet-strength and handling No hard spots or density variations No airborne fibers Custom cut Bulk packaging Ahlstrom 238: 0.34 mm ? 140 mm /30 min. This medium thick paper is recommended for general chromatography applications. Ahlstrom 238 is also ideal for use as wicks in protein or nucleic acid blotting to provide a uniform flow of buffer through the gel to the transfer membrane in a blotting sandwich. This is our most widely used blotting paper. Ahlstrom 238 is also suited for electrophoresis and the separation of inorganic compounds and for use in removing gels from glass supports. Blotting Paper 33 x 43 cm This listing is for Pack of 100
Ahlstrom offers a full range of glass microfiber filters manufactured from 100% pure borosilicate glass. Because of their intrinsic properties, glass microfiber filters have wide applications in many areas of laboratory analysis, especially when fine filtration and high loading capacity is required. Applications for Ahlstrom glass microfiber filters include environmental analysis for water, wastewater, testing of soils, air pollution and monitoring, research and process biochemistry, and gravimetric analysis involving ignition of samples. Ahlstrom glass microfiber filters are also found in the filtration of hot gases and liquids, and in pre-filtration. Laboratory analysis 100% pure borosilicate glass Rapid flow rate Fine particle retention 0.7m -; 3.1 m High loading capacity Chemical and thermal resistance (up to 500C) Long shelf life Brilliant white color reflecting more than 96% of visible light Custom cut Standard Glass Microfiber Filters Standard glass microfiber filters contain no binders or other additives that may cause interference to sensitive enzymatic or other chemical reactions. The unique characteristics of glass microfiber filters make its use particularly advantageous to laboratory filtration by enabling fast filtration of large volumes and difficult solutions without premature clogging. Ahlstrom 131: 1.0m -; Medium Speed This standard grade found in many environmental applications offers slightly more retention than Ahlstrom 111 with slightly lower filtration speed and loading capacity. Ahlstrom 131 is recommended for the collection of suspended solids in potable water and in industrial wastes. In biochemical tests, Ahlstrom 131 is suited for cell harvesting, liquid scintillation countin
Ahlstrom offers a full range of glass microfiber filters manufactured from 100% pure borosilicate glass. Because of their intrinsic properties, glass microfiber filters have wide applications in many areas of laboratory analysis, especially when fine filtration and high loading capacity is required. Applications for Ahlstrom glass microfiber filters include environmental analysis for water, wastewater, testing of soils, air pollution and monitoring, research and process biochemistry, and gravimetric analysis involving ignition of samples. Ahlstrom glass microfiber filters are also found in the filtration of hot gases and liquids, and in pre-filtration. Laboratory analysis 100% pure borosilicate glass Rapid flow rate Fine particle retention 0.7m -; 3.1 m High loading capacity Chemical and thermal resistance (up to 500C) Long shelf life Brilliant white color reflecting more than 96% of visible light Custom cut Standard Glass Microfiber Filters Standard glass microfiber filters contain no binders or other additives that may cause interference to sensitive enzymatic or other chemical reactions. The unique characteristics of glass microfiber filters make its use particularly advantageous to laboratory filtration by enabling fast filtration of large volumes and difficult solutions without premature clogging. Ahlstrom 161: 1.1m -; Medium Speed This popular grade offers finer particle retention and higher flow rate than traditional analytical filter papers. Ahlstrom 161 is used in general laboratory applications, cell harvesting, liquid scintillation counting, and in the monitoring of air and water pollution. Ahlstrom 161 is generally recommended for water pollution monitoring techniques for total suspended sol
Ahlstrom's qualitative grades of filter paper are, by definition, recommended for use in analytical methods, which determine or identify particulate constituents of a mixture irrespective of the amount present. Ahlstrom offers a complete range of low ash filter papers for general laboratory work that provides you with the correct combination of particle retention, filtration speed, loading capacity and wet-strength. Qualitative analysis, low ash content 0.06 percent, untreated, consistent performance, wet-strengthened grades, custom cut. These grades contain a high level of alpha-cellulose that provides high purity but will weaken when wet. The inherent strength of standard (untreated) grades does not pose a problem when they are used in routine quadrant folded applications. We do not recommend these grades for use in vacuum work or when wet handling is required.
Ahlstrom's qualitative grades of filter paper are, by definition, recommended for use in analytical methods, which determine or identify particulate constituents of a mixture irrespective of the amount present. Ahlstrom offers a complete range of low ash filter papers for general laboratory work that provides you with the correct combination of particle retention, filtration speed, loading capacity and wet-strength. Qualitative analysis, low ash content 0.06 percent, untreated, consistent performance, wet-strengthened grades, custom cut. These grades contain a high level of alpha-cellulose that provides high purity but will weaken when wet. The inherent strength of standard (untreated) grades does not pose a problem when they are used in routine quadrant folded applications. We do not recommend these grades for use in vacuum work or when wet handling is required. Ahlstrom 617 is also found in construction product testing and is used by students to retain large flocculents and precipitates.
Ahlstrom's qualitative grades of filter paper are, by definition, recommended for use in analytical methods, which determine or identify particulate constituents of a mixture irrespective of the amount present. Ahlstrom offers a complete range of low ash filter papers for general laboratory work that provides you with the correct combination of particle retention, filtration speed, loading capacity and wet-strength. Qualitative analysis, low ash content 0.06 percent, untreated, consistent performance, wet-strengthened grades, custom cut. These grades contain a high level of alpha-cellulose that provides high purity but will weaken when wet. The inherent strength of standard (untreated) grades does not pose a problem when they are used in routine quadrant folded applications. We do not recommend these grades for use in vacuum work or when wet handling is required. This grade is a slow flowing filter designed to retain fine particles encountered in qualitative analysis. Ahlstrom 610 is widely used for water analysis, biological products and fine precipitates such as coldprecipitated barium sulfate.
Air Force Blaster US Plug Car and Motorcycle Dryer by MetroVac. With Wall Mount Bracket. The MetroVac Air Force Blaster Car and Motorcycle Dryer offers car and motorcycle users the perfect tool to dry those stubborn and hard to reach vehicle parts. Producing warm, dry, filtered air, this powerful dryer makes it easy to remove water from your car or motorcycle with its 4 Peak HP, two-stage dual fan motor. Just flip the switch and the Air Force Blaster Car and Motorcycle Dryer will completely dry your bike in minutes and blasts water out of those hard to reach areas of your vehicle. The water evaporates before water spots or streaks will form; and will completely dry smaller cars.</p> <b>Key Features</b><ul> <li>Uses warm, dry, filtered air that provides a safe drying experience without the chance of scratching expensive paint and chrome finishes</li> <li>Front-end swivel wheels allow for added mobility</li></ul> <b>Specifications</b><ul> <li>Construction: Sturdy All Steel</li> <li>Motor: 8.0 Peak HP (two motors)</li> <li>Amps: 19 Amps</li> <li>Watts: 2,280 Watts</li> <li>Airflow: 58,500 ft./min./400 CFM</li> <li>Cord: 12 ft. Heavy Duty, 3 Conductor</li> <li>Dimensions: 22"x8"x11"</li> <li>Weight: 17 lbs</li> <li>Accessories: 30 ft. x 1.5" Flexible Commercial Strength hose, Heavy Duty Neoprene Blower nozzle plus 5 additional Interchangeable Attachments, Front Swivel Wheels, Wall Mount Bracket, Hose Hanger</li></ul>
Air Gun, Air Gun Body Style Pistol Grip, Air Gun Inlet Size 1/4 In. (F)NPT, 36 In. Extension Size, Lever Trigger, Output 2.0 LbF, Max. Inlet Pressure 120 psi, 34 scfm Air Consumption, 3/4 In.-32 (F)NPT Outlet Size, Nozzle Nylon Venturi, 2-3/8 In. Nozzle Length, Body Material Aluminum, Max. dBA 107, Color Metallic, Standards OSHA 1910.242(B)
Aircraft Toggle Micro Switch. P/N 2TL1-2 or MS24524-22. Alternate P/Ns MS24524, MS-24524-22, MS2454-22, ASC1560580, SS-00-28, W41262N6201B2, MIL-DTL-3950, MIL-S-3950, 00664-0026-0, 12074, 1347H70H22, 13MPE-301-016 PC 55, 22TL1-2, 2635-116-02 ITEM 1-3, 27G3150-1, 2TL1-2, 4186300-102, 45593L1, 45A0092, 45A0100, 4711 157130, 48342 28012, 504001-00-0022, 538075-22, 6415291, 812034-2002, 8501K9, 8501-K9, 9202811, 927439-0543, 96-23648, 00-655-4247. NSN: 5930-00-655-4247. It was removed from a salvage aircraft.