Brand: Mersen Products

All products from this brand (18 total)

Mersen AJT Amp-Trap 2000 SmartSpot time-delay/class J fuse with maximum circuit protection. It provide a visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No damage protection to main, feeder, and branch circuits, for all types of loads - yet, they require only half the mounting space needed for 600VAC class RK fuses. AJT's time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability. 300kA interrupting rating - self-certified, UL witnessed tests. Small footprint requires less mounting space and allows smaller, more economical fuse blocks. Easy 2-to-1 selectivity for prevention of nuisance shutdowns. Unique class J dimensions prevent replacement errors. High-visibility orange label gives instant brand recognition. Metal-embossed date and catalog number for traceability and lasting identification. Fiberglass body provides dimensional stability in harsh industrial settings. High-grade silica filler ensures fast arc quenching. Optional EI indicator/switch mount for open fuse indication. Use for motor circuits; mains; feeders; branch circuits; lighting, heating and general loads; transformers; control panels; circuit breaker back-up; bus duct and load centers. Highlights: SmartSpot indicator, time-delay, highly current-limiting, arc flash mitigating, DC ratings, optional mechanical indicator. Approvals: UL listed to standard 248-8 file E2137, DC listed to UL standard 248, CSA certified to standard C22.2 No. 248.8, IEC 269-2-1. UL listed, DC tested to UL standard 248. 600VAC/500VDC voltage rating. 200kA AC/100kA DC IR rating. 500 ampere current rating. Measures 2-1/2-inches diameter by 8-inches length.
Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2, 3 and 4 inch diameter barrels with ferrules and are mounted in spring reinforced clips. Defines fuses designed prior to the time where the ANSI standards defined the term "General Purpose" and do not meet all of the general purpose definition. These fuses are capable of interrupting all currents above 2.2 to 3 times the fuse's rated current up to its maximum interrupting rating. A general purpose current-limiting fuse is one that is capable of interrupting all currents from its rated interrupting current down to the current that causes melting of the fusible element in one hour or more. E-Rated fuses are general purpose fuses that operate: 100E or less must melt in 300 seconds at 200 to 240 percent of E rating. Over 100E must melt in 600 seconds at 220 to 264 percent of E rating. Example: A 100E fuse must melt in 300 seconds with an applied current of 200 to 240 amperes. These fuses were designed and originally tested at a higher maximum interrupting rating value. Features: Blown-fuse indicator to give positive identification of open fuse. 9F60: 0.125 pounds tripped force 0.20-inch. 15-inches clip centers suitable for use indoors or outdoor. Applications: Protection for 2.4kV to 34.5kV transformers or distribution systems. Highlights: E-Rated, UL listed, outdoor use. 15.5kV voltage rating. 50kA interrupt rating. 5E ampere current rating. Measures 2-inches diameter by 17-13/64-inches length.