As an Amazon Associate, we earn from qualifying purchases.

Murray . MP120DFP

Gallery

Attributes

Brand name, Manufacturer name, BrandMurray
ManufacturerMurray Siemens
AdultProduct, Autographed, Batteries_included, Batteries_required, Memorabilia, TradeInEligibleFalse
AsinB00R7Z9K0M
Bullet_pointLED Trip Indicators identify the cause of the last AFCI trip Satisfies AFCI/GFCI requirements set forth by 2014 NEC Save time and money by combining two safety devices into one
Circuit_breaker_typeAFCI
ClassificationId6355924011
Current_rating20.0
DisplayNameGround Fault Circuit Interrupters
Height1.199999998776 1000 15.494 500 75
Identifier0887621817299 887621817299
IdentifierTypeEAN UPC
ItemClassificationBASE_PRODUCT
ItemName, Item_nameMurray 20 Amp AFCI/GFCI Dual Function Circuit Breaker
Item_package_quantity, PackageQuantity1
Item_package_weight0.181
Item_type_keywordground-fault-circuit-interrupters
KeywordG2283937
Length3.048 6.099999993778
Linkhttps://m.media-amazon.com/images/I/4123AhdT9rL._SL75_.jpg https://m.media-amazon.com/images/I/4123AhdT9rL.jpg https://m.media-amazon.com/images/I/41qcID0XOJL._SL75_.jpg https://m.media-amazon.com/images/I/41qcID0XOJL.jpg https://m.media-amazon.com/images/I/61BTjh+LozL.jpg https://m.media-amazon.com/images/I/61jzo0umFlL.jpg https://www.amazon.com/gp/bestsellers/hi https://www.amazon.com/gp/bestsellers/hi/6355924011
ModelNumber, Model_number, Mpns, PartNumber, Part_number, StrippedMpnsMP120DFP
Number_of_poles2
ProductTypeCIRCUIT_BREAKER
Product_descriptionThe Dual Function Circuit Breaker combines GFCI and AFCI, protecting against both Arc Faults and Ground Faults. This, along with the new Self-Test and Lockout feature, makes it the first in class in electrical safety for homeowners. The 2014 National Electrical Code (NEC) now requires both Arc Fault and Ground Fault protection on kitchen and laundry circuits. Before the release of Dual Function Circuit Breakers, the only option to comply with this code was to pair an AFCI circuit breaker with a GFCI receptacle. The Dual Function Circuit breaker combines these 2 devices into once solution that provides both cost savings and less hassle in installation and maintenance. This is a win solution for everyone. Testing GFCI's and AFCI's on a monthly basis is a good idea that is sometimes forgotten. Underwriters Laboratories (UL) suggests that AFCI/GFCI devices be tested every 30 days after installation to ensure they are properly working. Now the new Self-Test and Lockout feature enables the Dual Function Circuit Breaker to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground/arc fault. This effortless system guarantees that only the best protection is given to your home at all times.
Product_site_launch_date2014-12-19T14:31:30.628Z
Rank157 678009
Supplier_declared_dg_hz_regulationnot_applicable
TitleGround Fault Circuit Interrupters Tools & Home Improvement
Typeean upc
Unitamps centimeters inches kilograms pounds volts
VariantMAIN PT01 PT02 PT03
Voltage120.0
WebsiteDisplayGrouphome_improvement_display_on_website
WebsiteDisplayGroupNameHome Improvement
Weight0.39903669422
Width1000 14.986 5.899999993982 500 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
Home Depot20548802111 @ $49.97

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Murray 20 Amp AFCI/GFCI Dual Function Circuit Breaker
Brand: Murray
The Dual Function Circuit Breaker combines GFCI and AFCI, protecting against both Arc Faults and Ground Faults. This, along with the new Self-Test and Lockout feature, makes it the first in class in electrical safety for homeowners. The 2014 National Electrical Code (NEC) now requires both Arc Fault and Ground Fault protection on kitchen and laundry circuits. Before the release of Dual Function Circuit Breakers, the only option to comply with this code was to pair an AFCI circuit breaker with a GFCI receptacle. The Dual Function Circuit breaker combines these 2 devices into once solution that provides both cost savings and less hassle in installation and maintenance. This is a win solution for everyone. Testing GFCI's and AFCI's on a monthly basis is a good idea that is sometimes forgotten. Underwriters Laboratories (UL) suggests that AFCI/GFCI devices be tested every 30 days after installation to ensure they are properly working. Now the new Self-Test and Lockout feature enables the Dual Function Circuit Breaker to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground/arc fault. This effortless system guarantees that only the best protection is given to your home at all times.
Details
  • LED Trip Indicators identify the cause of the last AFCI trip
  • Satisfies AFCI/GFCI requirements set forth by 2014 NEC
  • Save time and money by combining two safety devices into one
Analytics
Case Qty1 units
View on Amazon (paid link)