Oakton, WD-35805-09, Flushable PTFE Junction pH Electrode, Double-Junction, Epoxy-Body, Refillable. Features flushable PTFE junction use with substances that ordinarily clog standard electrodes. Ideal for testing dirty water, slurries, oils, paints, pastes, low ionic strength solutions, and solutions with heavy metals or organics. Flushable annular junction lets you refresh junction by pressing electrode cap cleans clogs instantly.
Penetration Temperature Probe, Type J, Grounded, For Application Semi-Soft, Soft, Mini Plug, Probe Size 5/32 in x 4 in, Cable Length 60 in, 32 Degrees to 400 Degrees F/0 Degrees to 204 Degrees C, Thermocouple, Thermowell Connection Mini Connector
pH Electrode, Double Junction, Testing Parameter pH, Measurement Range 0-14 pH, pH Range 0-14 pH Units, Tip Shape Round, Operating Temp. Range 0 Degrees to 80 Degrees C, Body Material Epoxy, Diameter 12 mm, Length 130 mm, Cable Length 3 ft, Connector BNC, Amplifier No, Temp. Sensor None, Max. Pressure Ambient, For Use With OAKTON pH Tutor Benchtop Meter, Standards NIST or USA, Shelf Life 6 mo, Reference Combination Electrode, Junction Double, Recommended Use pH measurement in the lab, or field
pH Electrode, Double-Junction, Testing Parameter pH, Measurement Range 0-14 pH, pH Range 0-14 pH Units, Tip Shape Round, Operating Temp. Range 0 Degrees to 80 Degrees C, Body Material Epoxy, Diameter 12mm, Length 130 mm, Cable Length 3 ft, Connector BNC, Amplifier No, Temp. Sensor None, Max. Pressure Ambient, For Use With OAKTON pHTestr BNC, Standards NIST or USA, Shelf Life 6 mo, Reference Combination Electrode, Junction Double, Electrolyte Redox
pH Electrode, Double-Junction/Refillable, Testing Parameter pH, Measurement Range 0-14 pH, pH Range 0-14 pH Units, Tip Shape Round, Operating Temp. Range 0 Degrees to 80 Degrees C, Body Material Glass, Diameter 12mm, Length 130 mm, Cable Length 3 ft, Connector BNC, Amplifier No, Temp. Sensor None, Max. Pressure Ambient, For Use With OAKTON pH 510 Meter, Standards NIST or USA, Shelf Life 6 mo, Reference Combination Electrode, Junction Double, Electrolyte Redox
pH Electrode, Single Junction, Testing Parameter pH, Measurement Range 0 - 14 pH, pH Range 0 - 14 pH, Tip Shape Round, Operating Temp. Range 32 Degrees to 100 Degrees C, Body Material Epoxy, Diameter 12 mm, Length 4.3 mm, Cable Length 3 ft, Connector BNC, Amplifier No, Reference Combination Electrode, Pin Type Junction, Junction Single, Electrolyte Combinaci?n de Electrodo
pH Electrode, Single-Junction, Testing Parameter pH, Measurement Range 0-14 pH, pH Range 0-14 pH Units, Tip Shape Round, Operating Temp. Range 0 Degrees to 80 Degrees C, Body Material Epoxy, Diameter 12 mm, Length 130 mm, Cable Length 3 ft, Connector BNC, Amplifier No, Temp. Sensor None, Max. Pressure Ambient, For Use With OAKTON 650 Series Multiparameter Meters, Standards NIST or USA, Shelf Life 6 mo, Reference Combination Electrode, Junction Double
Replacement Electrode for pH Spear, Double junction spear, Testing Parameter pH, Measurement Range 0-14 pH, pH Range 0-14 pH Units, Tip Shape Round, Operating Temp. Range 0 Degrees to 80 Degrees C, Body Material ABS Plastic, Diameter 1 in, Length 130 mm, Cable Length Direct connect, Connector OAKTON Connector, Amplifier No, Temp. Sensor None, Max. Pressure Ambient, For Use With OAKTON pH Spear, Standards NIST or USA, Shelf Life 6 mo, Junction Double junction spear, Includes Electrode