As an Amazon Associate, we earn from qualifying purchases.

PX3ULX05

Page description

Attributes

Brand name, Manufacturer nameVeris Industries
ManufacturerVeris Industries Veris
InStockString, IsBrandQueryTrue
Extra Product Name, MPN, SKU, Model, ModelNumber, Model_number, Mpns, PartNumber, Part_number, StrippedMpnsPX3ULX05
Weight0.5 0.35
WeightUnitlbs
moq, multiple, tierMinQty1, NumberOfItems, Number_of_items1
qtyInStock-2
qtySourceInStockString
tierPrice1404.14
ASIN, AsinB07MBH38YJ
AdultProduct, Autographed, Memorabilia, TradeInEligibleFalse
Amount0.00
Brand, Label, Publisher, StudioVeris
Bullet_pointAll variants are available with and without display Duct and panel models have two pressure and velocity range options:0-1" WC / 0-3,000 ft/min or 0-10" WC / 0-7,000 ft/min with seven field-selectable sub-ranges for pressure and eight for velocity The PX3 is available in three installation configurations: duct, panel or universal The PX3 transducer can measure either air pressure or velocity with the flip of a switch
Currency, CurrencyCodeUSD
Height1328 2011 334 375 419 50 500 56 63 667 75
ItemClassificationBASE_PRODUCT
ItemName, Item_name, TitleVeris,Pressure,Dry,Univ,LCD, PX3ULX05
Item_type_keywordelectronic-components-sensors
Item_weight0.35
KeywordSRS1 |
Linkhttps://m.media-amazon.com/images/I/31jCHV4RonL._SL75_.jpg https://m.media-amazon.com/images/I/31jCHV4RonL.jpg https://m.media-amazon.com/images/I/41RK2oaZ23L._SL75_.jpg https://m.media-amazon.com/images/I/41RK2oaZ23L.jpg https://m.media-amazon.com/images/I/41W6KnZ46zL._SL75_.jpg https://m.media-amazon.com/images/I/41W6KnZ46zL.jpg https://m.media-amazon.com/images/I/41cEF5m5QxL._SL75_.jpg https://m.media-amazon.com/images/I/41cEF5m5QxL.jpg https://m.media-amazon.com/images/I/51C88oaOyVL.jpg https://m.media-amazon.com/images/I/61JnaTGts9L.jpg https://m.media-amazon.com/images/I/71ORs3lKTEL.jpg
List_price0.0
ProductGroup, WebsiteDisplayGroupNameApparel
ProductType, ProductTypeNameELECTRONIC_COMPONENT
Product_descriptionMedia Compatibility Dry air or inert gas Input Power 12-30VDC or 24VAC nominal Output Field-selectable: 2-wire loop-powered 4-20mA (DC only clipped and capped) or 3-wire 0-5V/0-10V Pressure Ranges: Unidirectional: 0.1/0.25/0.5/1.0” W.C. F.S. (25 pa/50 pa/100 pa/250 pa F.S.) switch selectable; Bidirectional: ±0.1/±0.25/±0.5/±1.0” W.C. F.S. (±25 pa/±50 pa/±100 pa/±250 pa F.S.) switch selectable Response Time Standard: T95 in 20 sec Fast: T95 in 2 sec switch selectable Mode Unidirectional or bidirectional switch selectable Display (option) Signed 3-1/2 digit LCD indicates pressure overrange indicator Proof Pressure 3 psid (20.6kPa) Burst Pressure 5 psid (34.5kPa) Accuracy ±1% F.S. of selected range (combined linearity and hysteresis) Temperature Effect 1" 0.05%/°C; 10" Zero Drift (1-year) 1" 2.0% max. Zero Adjust Pushbutton auto-zero and digital input (2-pos terminal block) Operating Environment 0°- 60°C (32° to 140°F); 0 to 90% RH non-condensing Fittings Brass barb; 0.24” (6.1mm) o.d. Physical UL 94 V-O Fire Retardant ABS EMC Conformance: EN 61000-6-3:2001 Class B EN 61000-6-1:2001 EN 61000-3-2:2000 EN 61000-3-3:2001 EMC Test Methods: CISPR 22:1997 (Amended A1:2000 Class B A2:2002) IEC 61000-4-2:2002 IEC 61000-4-3:2006 IEC 61000-4-4:2004 IEC 61000-4-5:2001 IEC 61000-4-6:2004 IEC 61000-4-8:2001 IEC 61000-4-11:2004.EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper SURGE PROTECTION (EN 61000-6-1:2001 specification requirements).
Product_site_launch_date2019-01-03T08:00:00.000Z
SkuJAFLINE HD G52H3HDR100 RL875S-471K-RC TRACO POWER TMP 60105C TRACO POWER TRI3-1223
Style#N/A
URLhttps://m.media-amazon.com/images/I/31jCHV4RonL._SL75_.jpg
Unitpounds
Unitspixels pounds
VariantMAIN PT01 PT03 PT04
WebsiteDisplayGroupapparel_display_on_website
Width1000 2400 339 500 51 75 900

Distributor offers

SellerSKUMOQIn stockMultiplePrices
uri.comPX3ULX051-211 @ $404.14
midwestapplianceparts.comPX3ULX05-VE-P1-211 @ $177.20
midwestapplianceparts.comPX3ULX05 -VE-P11
gsistore.comPX3ULX0512711 @ $180.26
hvacdiscountstore.comVER--PX3ULX0512111 @ $185.02
ptacsolutions.comPX3ULX05111 @ $219.97
GalcoPX3ULX05-VEIN1211 @ $223.40
blackhawksupply.comPX3ULX051IN STOCK11 @ $151.55
alliedcontrols.comPX3ULX051Factory Stock11 @ $141.24
zotsupply.comPX3ULX051Ships in 1-2 Weeks11 @ $150.90
Voomi SupplyPX3ULX051-211 @ $180.38
globaltestsupply.comPX3ULX0514 to 5 Weeks1
KelePX3ULX05119711 @ $220.62

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Veris,Pressure,Dry,Univ,LCD, PX3ULX05
Brand: Veris
Media Compatibility Dry air or inert gas Input Power 12-30VDC or 24VAC nominal Output Field-selectable: 2-wire loop-powered 4-20mA (DC only clipped and capped) or 3-wire 0-5V/0-10V Pressure Ranges: Unidirectional: 0.1/0.25/0.5/1.0” W.C. F.S. (25 pa/50 pa/100 pa/250 pa F.S.) switch selectable; Bidirectional: ±0.1/±0.25/±0.5/±1.0” W.C. F.S. (±25 pa/±50 pa/±100 pa/±250 pa F.S.) switch selectable Response Time Standard: T95 in 20 sec Fast: T95 in 2 sec switch selectable Mode Unidirectional or bidirectional switch selectable Display (option) Signed 3-1/2 digit LCD indicates pressure overrange indicator Proof Pressure 3 psid (20.6kPa) Burst Pressure 5 psid (34.5kPa) Accuracy ±1% F.S. of selected range (combined linearity and hysteresis) Temperature Effect 1" 0.05%/°C; 10" Zero Drift (1-year) 1" 2.0% max. Zero Adjust Pushbutton auto-zero and digital input (2-pos terminal block) Operating Environment 0°- 60°C (32° to 140°F); 0 to 90% RH non-condensing Fittings Brass barb; 0.24” (6.1mm) o.d. Physical UL 94 V-O Fire Retardant ABS EMC Conformance: EN 61000-6-3:2001 Class B EN 61000-6-1:2001 EN 61000-3-2:2000 EN 61000-3-3:2001 EMC Test Methods: CISPR 22:1997 (Amended A1:2000 Class B A2:2002) IEC 61000-4-2:2002 IEC 61000-4-3:2006 IEC 61000-4-4:2004 IEC 61000-4-5:2001 IEC 61000-4-6:2004 IEC 61000-4-8:2001 IEC 61000-4-11:2004.EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper SURGE PROTECTION (EN 61000-6-1:2001 specification requirements).
Details
  • The PX3 transducer can measure either air pressure or velocity with the flip of a switch
  • The PX3 is available in three installation configurations: duct, panel or universal
  • Duct and panel models have two pressure and velocity range options:0-1" WC / 0-3,000 ft/min or 0-10" WC / 0-7,000 ft/min with seven field-selectable sub-ranges for pressure and eight for velocity
  • All variants are available with and without display
Listing
Product groupApparel
Product typeELECTRONIC_COMPONENT
ModelPX3ULX05
Part numberPX3ULX05
Items per pack1
LabelVeris
ManufacturerVeris
View on Amazon (paid link)