As an Amazon Associate, we earn from qualifying purchases.

Guard switch, Telemecanique Safety switches XCS, XCSPL, elbowed flush lever, centred, 1NC+1 NO, Pg11 | Mayer Electric

Gallery

Attributes

Brand name, Manufacturer name, ManufacturerSQUARE D
DimensionUnitmm
Extra Product NameGuard switch, Telemecanique Safety switches XCS, XCSPL, elbowed flush lever, centred, 1NC+1 NO, Pg11 | Mayer Electric
UPC3389110866506
Weight0.095
WeightUnitkg
Weight_AttribNet Weight
depth, length, width30.0
height322.0
height_AttribHeight
jsonUrlData/Product/SQUARE-D-Guard-switch-Telemecanique-Safety-switches-XCS-XCSPL-elbowed-flush-lever-centred-1NC1-NO-Pg11-3389110866506
jsonUrlData2be8581f4-d3b4-4892-b621-aeea00585606
length_AttribDepth
moq, multiple, tierMinQty11
MPN, SKUSQDXCSPL581
qtyInStock0
tierPrice1106.34
width_AttribWidth
Contacts Type And Composition1 NC + 1 NO
Range Of ProductTelemecanique Safety switches XCS
Insulationdouble insulated
Cable Entry1 entry tapped Pg 11
Clamping Connection Capacity1 x 0.5...2 x 1.5 mm? with or without cable end
Contact Operationslow-break, break before make
Type Of Operatorelbowed flush lever
Electrical Connectionterminal
Product Or Component Typeguard switch
Component NameXCSPL
Operator Direction Informationcentred
Materialplastic
Number Of Poles2
Head Typeturret head rotary lever
Warranty18 months
Height161-161 mm
[Ui] Rated Insulation Voltage300 VUL 508 || 300 VCSA C22.2 No 14 || 500 V 3)EN/IEC 60947-1
Short-Circuit Protection10 A cartridge fuse gG (gl)
Positive Openingwith NC contact
Positive Opening Minimum Torque0.25 N.m
Mechanical Durability1000000 cycles
[Ithe] Conventional Enclosed Thermal Current10 A
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Materialpolyamide PA66 fibre glass impregnated
Lever Materialstainless steel
Tripping Angle5 ?
Width, Depth30 mm
Cable Outer Diameter7-10 mm
Minimum Torque For Tripping0.1 N.m
Net Weight0.095 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-5-1
Maximum Resistance Across Terminals30 mOhm EN/IEC 60947-5-4
Circularity ProfileENVEOLI110603EN
Rohs Exemption Information, Mercury FreeYes
Environmental DisclosureENVPEP110606EN
Sustainable Offer StatusGreen Premium product
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
Product CertificationsBG || UL || CSA
Ambient Air Temperature For Operation-25-70 ?C
Ambient Air Temperature For Storage-40-70 ?C
StandardsUL 508 || EN 1088/ISO 14119 || EN/IEC 60947-5-4 || EN/ISO 12100 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/IEC 60204-1
Electrical Shock Protection Classclass II EN/IEC 61140
Shock Resistance50 gn 11 ms IEC 60068-2-27
Vibration Resistance50 gn 10-500 Hz)IEC 60068-2-6
Protective TreatmentTC || TH
Ip Degree Of ProtectionIP67 conforming to IEC 60529

Distributor offers

SellerSKUMOQIn stockMultiplePrices
mayerelectric.comSQDXCSPL581111 @ $106.34