As an Amazon Associate, we earn from qualifying purchases.

Variable speed drive, Altivar Process ATV900, ATV930, 5,5 kW, 200/240 V, with braking unit, IP21 | Mayer Electric

Gallery

Attributes

Brand name, Manufacturer name, ManufacturerMayer Electric Supply
DimensionUnitmm
Extra Product NameVariable speed drive, Altivar Process ATV900, ATV930, 5,5 kW, 200/240 V, with braking unit, IP21 | Mayer Electric
UPC785901058847
Weight7.7
WeightUnitkg
Weight_AttribNet Weight
depth, length236.0
height409.0
height_AttribHeight
jsonUrlData/Product/SCHNEIDER-ELECTRIC-Variable-speed-drive-ATV930-5-5kW-200-240V-with-braking-unit-IP21-785901058847
jsonUrlData287bc8e8f-bdfa-4249-9be1-abd20061dddc
length_AttribDepth
moq, multiple, tierMinQty1, Quantity Per Set1
MPNATV930U55M3
qtyInStock0
SKUSQDATV930U55M3
tierPrice13358.83
width171.0
width_AttribWidth
Prospective Line Isc50 kA
Network Frequency50-60 Hz
Product Destinationasynchronous motors || synchronous motors
Line Current20.2 A 200 V normal duty) || 15.1 A 200 V heavy duty) || 17.1 A 240 V normal duty) || 13.0 A 240 V heavy duty)
Phase3 phase
Asynchronous Motor Control Profilevariable torque standard || constant torque standard || optimized torque mode
Variantstandard version || with braking chopper
Product Or Component Typevariable speed drive
Apparent Power7.6 kVA 240 V normal duty) || 6 kVA 240 V heavy duty)
Ip Degree Of ProtectionIP21
Switching Frequency2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Transient Current30.5 A 60 s normal duty) || 28.1 A 60 s heavy duty)
Communication Port ProtocolModbus TCP || EtherNet/IP || Modbus serial
Product Specific Applicationprocess for industrial
Maximum Horse Power Rating7.5 hp normal duty || 5.0 hp heavy duty
Degree Of ProtectionUL type 1
Maximum Output Frequency599 Hz
Range Of ProductAltivar Process ATV900
Motor Power Kw5.5 kW normal duty || 4.0 kW heavy duty
[Us] Rated Supply Voltage200...240 V - 15...10 %
Mounting Modewall mount
Discrete Input Logic16 preset speeds
Continuous Output Current25.4 A 4 kHz normal duty || 18.7 A 4 kHz heavy duty
Nominal Switching Frequency4 kHz
Emc Filterintegrated || with EMC plate option
Device ApplicationIndustrial Application
Synchronous Motor Control Profilepermanent magnet motor || synchronous reluctance motor
Power Dissipation In Wnatural convection 47 W 200 V 4 kHz || forced convection 179 W 200 V 4 kHz
Analogue Output Typesoftware-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
4 Quadrant Operation Possible, With Safety Function Safe Stop 1 (Ss1), With Safety Function Safe Brake Management (Sbc/Sbt), With Safety Function Safe Torque Off (Sto), Brake Chopper Integrated, With Safety Function Safely Limited Speed (Sls)true
Exchange Modehalf duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Local Signallinglocal diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Data Format8 bits, configurable odd, even or no parity Modbus serial
Relative Symmetric Network Frequency Tolerance5 %
Net Weight7.7 kg
With Safety Function Safe Direction (Sdi), With Safety Function Safe Position (Sp), With Safety Function Safely Limited Position (Slp), With Safety Function Safe Operating Stop (Sos), With Sft Fct Safe Stop 2 (Ss2), With Safety Function Safe Speed Monitor (Ssm), With Safety Function Safe Programmable Logicfalse
Type Of Polarizationno impedance
Relay Output Typeconfigurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Analogue Input Number, Relay Output Number3
Motor Slip Compensationadjustable || automatic whatever the load || can be suppressed || not available in permanent magnet motor law
Discrete Output Number, Analogue Output Number2
Transmission Rate10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Method Of Accessslave Modbus TCP
Number Of Addresses1-247
Discrete Input Number10
Linearity ErrorAI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Width171 mm
Depth236 mm
Analogue Input TypeAI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Sampling Duration2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Electrical Connectioncontrol screw terminal 0.5...1.5 mm? AWG 20...AWG 16 || line side screw terminal 6 mm? AWG 10 || DC bus screw terminal 6 mm? AWG 10 || motor screw terminal 10 mm? AWG 8
Height409 mm
Acceleration And Deceleration Rampslinear adjustable separately from 0.01...9999 s
Maximum Output Voltage240.0 V
Base Load Current At High Overload18.7 A
Transmission FrameRTU
Base Load Current At Low Overload25.4 A
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 ?C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 ?C analog output
Input CompatibilityDI1...DI8 discrete input level 1 PLC EN/IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
Connector Type2 RJ45 || 1 RJ45
Physical InterfaceEthernet || 2-wire RS 485
Minimum Switching Currentrelay output R1, R2, R3 5 mA 24 V DC
Refresh Timerelay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolationbetween power and control terminals
Braking To Standstillby DC injection
Mercury Free, Rohs Exemption InformationYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
UpgradeabilityUpgraded components available
Environmental DisclosureENVPEP1508010EN
Sustainable Offer StatusGreen Premium product
California Proposition 65 : WARNING: This product can expose you to chemicals includingLead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI1508010EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Product CertificationsUL || T?V || CSA
Maximum Deflection Under Vibratory Load (During Operation)1.5 mm at 2...13 Hz

Distributor offers

SellerSKUMOQIn stockMultiplePrices
mayerelectric.comSQDATV930U55M3111 @ $3358.83