As an Amazon Associate, we earn from qualifying purchases.

Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 1NC+1 NO, booted pushbutton | Mayer Electric

Gallery

Attributes

Brand name, Manufacturer name, ManufacturerMayer Electric Supply
DimensionUnitm
Extra Product NameLatching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 1NC+1 NO, booted pushbutton | Mayer Electric
UPC785901992653
Weight0.865
WeightUnitkg
Weight_AttribNet Weight
jsonUrlData/Product/SQUARE-D-Latching-emergency-stop-rope-pull-switch-Telemecanique-rope-pull-switches-XY2C-e-XY2CH-1NC1-NO-booted-pushbutton-785901992653
jsonUrlData2c5fee10a-9205-4315-9ef3-ade40063c162
length30.0
length_AttribTrigger Cable Maximum Length
moq, multiple, tierMinQty1, Number Of Cables1
MPNXY2CH13250
qtyInStock0
SKUSQDXY2CH13250
tierPrice1409.32
Range Of ProductTelemecanique Emergency stop rope pull switches XY2C
Product Or Component Typelatching emergency stop rope pull switch
Housing Colourred RAL 3000
Overvoltage Categoryclass I EN/IEC 61140 || class I NF C 20-030
Device Short Name, Compatibility CodeXY2CH
Warranty18 months
Resetby booted push-button
Terminals Description Iso N?1(13-14)NO || (21-22)NC
Short-Circuit Protection10 A cartridge fuse gG EN/IEC 60269
Positive Openingwith EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current10 A
MarkingCE
Local Signallingwithout pilot light
Net Weight0.865 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-1
Trigger Cable Maximum Length30 m
Connections - Terminalsscrew clamp terminal, 1 x 0.5...2 x 1.5 mm?
Contacts Type And Composition1 NC + 1 NO
[Ui] Rated Insulation Voltage500 V 3)EN/IEC 60947-1 || 300 VUL 508
[Ie] Rated Operational Current3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operationslow-break
Distance Between Cable Supports5-5 m
Mechanical Durability800000 cycles
Cable Entry Number3 tapped entry Pg 13.5 cable gland
Body Materialzamak
Trigger Cable Anchor PointRH or LH side
Safety Reliability DataB10d = 4000000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Cover Materialstainless steel
Tightening Torque0.8-1.2 N.m
Maximum Resistance Across Terminals25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Rohs Exemption Information, Mercury FreeYes
Environmental DisclosureENVPEP111159EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Ambient Air Temperature For Operation-25-70 ?C
StandardsEN/IEC 60947-5-1 || EN/IEC 60204-1 || machinery directive 2006/42/EC || EN/IEC 60947-5-5 || EN/ISO 13850 || work equipment directive 2009/104/EC
Product CertificationsUL category NISD emergency stop devices || CCC
Shock Resistance50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance10 gn 10-150 Hz)EN/IEC 60068-2-6
Ip Degree Of ProtectionIP65 IEC 60529
Ambient Air Temperature For Storage-40-70 ?C
Protective TreatmentTC

Distributor offers

SellerSKUMOQIn stockMultiplePrices
mayerelectric.comSQDXY2CH13250111 @ $409.32