# Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 1NC+1 NO, booted pushbutton | Mayer Electric

**Manufacturer:** Mayer Electric Supply  
**MPN:** `XY2CH13250`

## Specifications

| Attribute | Value |
| --- | --- |
| Brand name | Mayer Electric Supply |
| Manufacturer name | Mayer Electric Supply |
| Manufacturer | Mayer Electric Supply |
| DimensionUnit | m |
| Extra Product Name | Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 1NC+1 NO, booted pushbutton \| Mayer Electric |
| UPC | 785901992653 |
| Weight | 0.865 |
| WeightUnit | kg |
| Weight_Attrib | Net Weight |
| jsonUrlData | /Product/SQUARE-D-Latching-emergency-stop-rope-pull-switch-Telemecanique-rope-pull-switches-XY2C-e-XY2CH-1NC1-NO-booted-pushbutton-785901992653 |
| jsonUrlData2 | c5fee10a-9205-4315-9ef3-ade40063c162 |
| length | 30.0 |
| length_Attrib | Trigger Cable Maximum Length |
| moq | 1 |
| MPN | XY2CH13250 |
| multiple | 1 |
| qtyInStock | 0 |
| SKU | SQDXY2CH13250 |
| tierMinQty1 | 1 |
| tierPrice1 | 409.32 |
| Range Of Product | Telemecanique Emergency stop rope pull switches XY2C |
| Product Or Component Type | latching emergency stop rope pull switch |
| Housing Colour | red RAL 3000 |
| Overvoltage Category | class I EN/IEC 61140 \|\| class I NF C 20-030 |
| Device Short Name | XY2CH |
| Warranty | 18 months |
| Reset | by booted push-button |
| Number Of Cables | 1 |
| Terminals Description Iso N?1 | (13-14)NO \|\| (21-22)NC |
| Short-Circuit Protection | 10 A cartridge fuse gG EN/IEC 60269 |
| Positive Opening | with EN/IEC 60947-5-1 |
| [Ithe] Conventional Enclosed Thermal Current | 10 A |
| Marking | CE |
| Local Signalling | without pilot light |
| Net Weight | 0.865 kg |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-1 |
| Trigger Cable Maximum Length | 30 m |
| Connections - Terminals | screw clamp terminal, 1 x 0.5...2 x 1.5 mm? |
| Contacts Type And Composition | 1 NC + 1 NO |
| [Ui] Rated Insulation Voltage | 500 V 3)EN/IEC 60947-1 \|\| 300 VUL 508 |
| [Ie] Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A \|\| 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A |
| Contact Operation | slow-break |
| Distance Between Cable Supports | 5-5 m |
| Mechanical Durability | 800000 cycles |
| Cable Entry Number | 3 tapped entry Pg 13.5 cable gland |
| Compatibility Code | XY2CH |
| Body Material | zamak |
| Trigger Cable Anchor Point | RH or LH side |
| Safety Reliability Data | B10d = 4000000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
| Cover Material | stainless steel |
| Tightening Torque | 0.8-1.2 N.m |
| Maximum Resistance Across Terminals | 25 MOhm EN/IEC 60255-7 category 3 \|\| 25 MOhm NF C 93-050 method A |
| Rohs Exemption Information | Yes |
| Mercury Free | Yes |
| Environmental Disclosure | ENVPEP111159EN |
| Sustainable Offer Status | Green Premium product |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Ambient Air Temperature For Operation | -25-70 ?C |
| Standards | EN/IEC 60947-5-1 \|\| EN/IEC 60204-1 \|\| machinery directive 2006/42/EC \|\| EN/IEC 60947-5-5 \|\| EN/ISO 13850 \|\| work equipment directive 2009/104/EC |

## Distributor availability

| Distributor | SKU | Price (USD) | Qty | Stock | MOQ |
| --- | --- | --- | --- | --- | --- |
| mayerelectric.com | SQDXY2CH13250 | 409.32 | 1 | None | 1 |

---
Structured data: `/python/html6/product/500/130000000/130440000/part_--XY2CH13250---MayerElectricSupply--9dad935b99.json`  
Search API: https://www.dataalchemy.com/api/  
MCP server: https://www.dataalchemy.com/mcp