ICM Controls ICM6701 Water Heater Direct Spark Ignition ControlDescription:With a heat call from the thermostat; the ICM6701 will begin a 15 second on delay, after the delay the gas valve and spark ignitor are energized and the control will check for the presence of flame. Once flame is detected the spark ignitor is turned off while the gas valve remains energized. Once the thermostat’s demand for heat ends, the gas valve is immediately de-energized.If flame is not sensed after 7 seconds, another 15 second on delay will begin followed by a second ignition sequence. If flame has not been